DROPPER SCREEN
4. Select Small Product or Large Product Deflector plate and install on Feeder Discharge
nose using screws provided. Brass hold down guide fingers should not hang
substantially below the dropper forks.
5. Turn Dropper ON in the Dropper Screen. See Dropper Screen settings below for details.
6. Make sure Dropper Cover is closed. Dropper and Feeder will not operate with cover
open. Dropper will operate in manual mode with the cover open.
7. When Dropper is turned ON, then when a Trigger Signal is received or the Cycle button
is pressed: the dropper forks will retract, then start to extend, then the feeder will start
next Batch Size and continue until Batch Size is complete. Sequence will repeat with
each new Trigger Signal or push of the Cycle button. When Dropper is Turned OFF,
Feeder will run as normal.