background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS

42" B-VENTED GAS APPLIANCES
P/N 725,007M  REV. G  07/2004

Millivolt Models

Electronic Models

BBV-42RMN

BBV-42REN

BBV-42RMP

BBV-42REP

MODELS

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odiur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

STANDARD SERIES

WH Report No. J99025850

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

Summary of Contents for STANDARD SERIES and

Page 1: ...LO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil...

Page 2: ...vides safe efficient operation External electri cal power is required to operate these units GENERAL INFORMATION Note Installation and repair should be per formedbyaqualifiedserviceperson Theappli an...

Page 3: ...SURED ENVIRONMENTS PRESSUREWITHINTHEHOMEISLESS THAN PRESSURES OUTSIDE SIGNIFI CANT NEGATIVELY PRESSURED ENVI RONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAYIMPACTTHEOPERATIONOFTHESE APPLIA...

Page 4: ...pliance area clear and free from combustible materials gasoline and other flammable liquids Honeywell Electronic Gas Valve WARNING FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULDBEOPERATEDONL...

Page 5: ...ance and call a qualified service technician The control lever snaps into place at either extreme of its range of motion When locked in position all the way to the right the damper is open When locke...

Page 6: ...LECTRICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer ed...

Page 7: ...on Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Ember Ma...

Page 8: ...re 12 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front burner a...

Page 9: ...tch Attachment Only Limit Switch BK WHT BK BK BK SIT Millivolt Wiring Diagram For Wall Switch Attachment Only If any of the original wire as supplied must be replaced it must be replaced with Type AWM...

Page 10: ...s go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor...

Page 11: ...Ne touchez aucun commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter...

Page 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Page 13: ...aire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la...

Page 14: ...essure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on thermogenerator Figure 9 Clean and or adjust pilot for maximum f...

Page 15: ...surements Must Be Taken While The Igniter Is Powered When Measured Voltage At Connections Use Care To Assure Terminals Are Not Damaged Replace Valve Replace Valve 24 Volt Hot End View Of Control Harne...

Page 16: ...he description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or ap plication of this syst...

Page 17: ...RCL is designed to operate with all millivolt ignition systems as well as electronic ignition systems It may be installed with use for either natural or propane gas appliances The RCL offers ease of...

Page 18: ...4001 1 74L8801 1 11 Bag of Rockwool 88L53 1 88L53 1 12 Limit Switch 62L1601 1 62L1601 1 13 Damper Switch 82L5901 1 82L5901 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No...

Page 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e 13 12 27...

Page 20: ...25 007M REV G 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Reviews: