background image

6

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Do not attempt to repaint the appliance until the 

finish is completely cured (see 

Burn-In Period 

on 

Page 3

)

. If the surface later becomes stained 

or marred, it may be lightly sanded and touched 

up with spray paint. 

Front  Glass  enclosure  panel,  removal 

and installation

     

WarninG

Handle  this  glass with extreme 

care!  tempered glass is suscep-

tible to damage – do not scratch 

or  handle  roughly  while  rein-

stalling the glass door frame.

     

WarninG

do not operate appliance with 

the glass front removed, cracked 

or  broken.    replacement  of 

the glass should be done by a 

licensed  or  qualified  service 

technician.

     

WarninG

do not attempt to substitute the 

materials used on this door, or 

replace cracked or broken glass 

with  any  materials  other  than 

those provided by the appliance 

manufacturer.

    

 WarninG

the  glass  door  of  this  appli-

ance must only be replaced as 

a complete unit as provided by 

the manufacturer.  do not attempt 

to  replace  broken,  cracked  or 

chipped glass separately.

     

WarninG

do not attempt to touch the front 

enclosure glass with your hands 

while the fireplace is in use.

These  are  direct-vent  appliances.  They  are 

designed to operate only when the front glass 

enclosure panel is installed.  Generally the front 

glass enclosure panel should not be removed ex-

cept to gain access to the components within the 

firebox, and the appliance may only be operated 

without the front glass enclosure panel in place 

for very brief periods of time during appliance 

checkout and adjustment. 

 

Note: 

The  flame  appearance  will  be  dimin-

ished while the front glass enclosure panel is 

removed.

During  this  appliance  checkout  and  adjust-

ment period, a potential safety hazard exists 

eXercise  eXtreMe  caution

  to  prevent 

the occurrence of any burn injuries from the 

exposed flames or hot surfaces.  Also note, that 

while the front glass enclosure panel (or any of 

the panels) is removed, the flame appearance 

will appear to be smaller than normal.

Figure 6 

instaLLinG  GLass door

top Flange on

Glass door

Bottom Vee-flange

Glass door

Glass door Latch

Glass door

Firebox Floor

removing Glass enclosure panels

(see 

Figure 6

)

.

 Remove the top louver assembly by lifting 

it up and pulling it out.

2.

 Remove  the  control  compartment  access 

door (see removal instructions on 

Page 3 

Removing Control Compartment Door).

3.

 Locate the two (2) latches at the top of the 

control compartment. To disengage the two 

latches from the bottom vee-flange of the 

glass enclosure panel, reach for the handles 

located towards the back of the latches and 

pull the handles down toward the front of 

the appliance.

4. 

Swing the bottom of the door out and raise 

it slightly to lift the top flange of the door 

frame away from the appliance.

installing Glass enclosure panels

(see 

Figure 6)

.

 Visually inspect the gasket on the backside 

of the glass panel. The gasket surface must 

be  clean,  free  of  irregularities  and  seated 

firmly.

2. 

Position the glass enclosure panel in front 

of the firebox opening at a 45 degree angle 

and engage the top flange over the lip at the 

top of the firebox opening. 

See Figure 6.

3. 

Swing the glass enclosure panel down and 

back.  Ensure the gasket seats evenly as the 

panel draws shut.  Engage the Vee-flange at 

the bottom of the panel with the latches and 

close the latches to secure the panel.

4.

 Reinstall top louver assembly and control 

compartment door see installation instruc-

tions  on 

Page  3, 

Reinstalling  Control 

Compartment Door).

Summary of Contents for SSDVR-3328C

Page 1: ...u de tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dan...

Page 2: ...lves millivolt models NATURAL PROPANE GAS Models Input Rate BTU HR SSDVT R 3328 17 500 high 13 500 low Table 1 Provide adequate clearances around air open ings and adequate accessibility clearance for...

Page 3: ...re The gas valve for electronic systems is also located below the glass enclosure panel See Figure 1 Reinstalling Control Compartment Door Toreinstall insertthehookcatchesoneachside of the door into t...

Page 4: ...ell Millivolt Gas Valve Figure 5 O N OFF P I L OT L O H I OFF ON OFF ON Figure 3 Optional Blower OFF ON Rocker Switch SIT Millivolt Gas Valve Gas Outlet Gas Inlet Pilot Adjustment Screw Terminals TPTH...

Page 5: ...see Page 23 for ordering information Re Install Embers Logs and Volcanic Stone Carefully follow placement instructions on Pages 7 to 9 All logs should fit onto cor responding pins and or log stoppers...

Page 6: ...ut and adjust ment period a potential safety hazard exists EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front gla...

Page 7: ...t the rear log on the raised log support brackets at the rear of the firebox fitting the slots in the logs over the brackets 2 Position the front log with the pins for the two side twigs in the up pos...

Page 8: ...NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Page 9: ...ew more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation...

Page 10: ...ANCAUSEIMPROPERAND DANGEROUS APPLIANCE OPERATION Figure 13 3 8 to 1 2 9 13 mm Ground Electrode Flame Rod Hot Surface Igniter Proper Flame Adjustment Pilot Nozzels ELECTRONIC PILOT ASSEMBLY Proper Pilo...

Page 11: ...icsattacheddirectlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Ty...

Page 12: ...12 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Page 13: ...perature variables using the hand held remote control transmitter The Model RCL T Deluxe remote control system is installed in the same manner as the standard system may be operated with electronic an...

Page 14: ...vers Kits These kits include a top 4 louver assembly and a bottom 4 louver assembly They provide a touch of elegance These kits can be retrofitted to previously installed appliances Door Frame Kits A...

Page 15: ...l painted surfaces may be accomplished with the touch up paint kit PA I N T Bag of Glowing Embers Bag of Volcanic Stone Replacement ember materials or volcanic stone are available for use with these a...

Page 16: ...ualified service technician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician...

Page 17: ...ecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le service des incendies C N utilisez que votre main pour manipuler le bouton de r...

Page 18: ...gas control which has been under water Lighting Instructions Electronic 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Turn the OFF ON switch to OFF D...

Page 19: ...s l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquel...

Page 20: ...eral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualif...

Page 21: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Page 22: ...common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check tra...

Page 23: ...s Fireplace Assembly 1 1 d o o H 1 1 1 r Upper e v u o L 2 1 1 Lower r e v u o L 3 4 Enclosure Glass Front Complete 1 1 5 Nameplate Brand 56L93 1 56L93 1 2 2 h c t a L 6 7 Catch Door Magnetic 69L31 1...

Page 24: ...e in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 R...