CAUTION: Wear gloves and safety glasses
for protection while doing required
maintenance.
WARNING
Turn OFF gas and electrical
power to the fireplace and allow
it to cool before cleaning or
servicing the appliance.
MAINTENANCE
(See Maintenance Schedule, Page 50)
Refer to the maintenance schedule for
maintenance tasks, procedures, frequency and
by whom they should be performed. Always
verify proper operation of the appliance after
servicing.
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service technician
(inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged).
Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Glass Cleaning
See
Front Glass Enclosure Panel, Removal and
Installation
on
Page 39
.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne
adéquatement une fois l'entretien
terminé.
Always turn off the gas before cleaning.
Before re-lighting, refer to the lighting
instructions in this manual. Instructions
are also found on a pull-out panel located
in the control compartment.
Always keep the appliance area clear
and free from combustible materials,
gasoline and other flammable liquids.
Before re-lighting the fireplace, refer
to the lighting instructions in this
manual. Instructions are also found on
pull-out panels located in the control
compartment.
Inspect Venting System
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS
Lighting the Appliance
To light electronic appliances refer to the detailed
lighting instructions found on
Page 48
of these
instructions. Instructions can also be found on
the pull-out lighting instruction labels attached
to the gas control valve.
POWER VENT OPERATION
Operating Instructions for the Appliance
To turn ON the appliance with the receiver:
1. Manually slide the ON/REMOTE/OFF switch
to the ON position.
2. Blower should start immediately.
3. Igniter starts sparking and pilot will light.
4. Burner should light after a few seconds.
To turn ON the appliance with the remote
transmitter:
1. Manually slide the ON/REMOTE/OFF switch
to the REMOTE position, then press the ON/
OFF key on the transmitter.
2. Blower should start immediately.
3. Igniter starts sparking and pilot will light.
4. Burner should light after a few seconds.
To Turn OFF
1. Manually slide the ON/REMOTE/OFF switch
to the OFF position or press the ON/OFF key
on the transmitter.
2. Burner and pilot should turn off immediately.
3. Blower will continue to run for about 15
seconds, then the blower will stop.
16.17
(411 mm)
15.92
(404 mm)
10.00
(254 mm)
11.19
(284 mm)
13.50
(343 mm)
Top View
Front View
16.17
(411 mm)
15.92
(404 mm)
10.00
(254 mm)
11.19
(284 mm)
13.50
(343 mm)
Top View
Front View
Figure 53 - Power Vent Termination Specifications