background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY READ BEFORE LIGHTING

A.

This appliance has a pilot which must  be lighted with a piezo
ignitor. When lighting the pilot, follow these instructions
exactly.

B. BEFORE OPERATING

 smell all around the appliance area for

gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.

2.

For complete shutdown, turn remote wall switch to “OFF.”

3.

Access the lower control compartment.

4.

Depress gas control knob slightly and turn clockwise
                to “OFF.” Do not force.

5.

Close lower control compartment.

LIGHTING INSTRUCTIONS

1. STOP! 

Read the safety information above on this page.

2.

Access the lower control compartment.

3.

Turn remote wall switch to “OFF.”

4.

Verify main line shut-off valve is open.

5.

Push in gas control knob slightly and turn clockwise
                to “OFF.”

6.

Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this page. If you
do not smell gas, go to the next step.

7.

Push in gas control knob slightly and turn counterclockwise
                  to “PILOT.”

8.

Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark ignitor (pushing the button) until pilot
lights. Continue to hold the control knob in for about  1 

¹⁄₂

 minutes

after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.

If pilot will not stay lit after several
tries, turn the control knob to “OFF”
and  call your service technician or
gas supplier.

9.

Turn gas control knob counterclockwise
to “ON.”

10.

Close lower control compartment.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart-
ment.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician.
Force or attempted repair may result in a fire or an explosion.

D.

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.

Note: 

Knob cannot be turned from “PILOT” to “OFF”

unless the knob is pushed in slightly. Do not force.

CONTROL KNOB

Summary of Contents for GHC-6500 SERIES

Page 1: ...tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le bati...

Page 2: ...absence of local codes installation must be in accordance with the National Electrical Code NFPA 70 latest edition In Canada thecurrentCSAC22 1CanadianElectricCode DO NOT ATTEMPT TO ALTER OR MODIFY T...

Page 3: ...ES USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE WARNING DO NOT PLACE CLOTHING OR...

Page 4: ...near the gas valve in the control compartment 4 Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids 5 Remember Millivolt appliances have a co...

Page 5: ...ck on Adjustment To adjust the flame position the air shutter to the nominal setting Figure 10 Allow the burner to operate for at least 30 minutes Observe the flame continuously If it appears weak or...

Page 6: ...Accomplishing Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacin...

Page 7: ...l valve If a higher than normal temperature is sensed due to a blocked vent or prolonged downdraft the limit switch will open and cause the burner to shut off The pilot flame should be steady not lift...

Page 8: ...D CAREFULLY THEY WILL STAND UP INDEFINITELY TO EX TREMETEMPERATURES HOWEVER THEY AREVERYFRAGILEANDARESUSCEPTIBLE TO CRUSHING AND OR BREAKAGE IF HANDLED ROUGHLY Figure 14 GHC GRD 6500 LOG PLACEMENT A B...

Page 9: ...e for refer ence purposes only This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment CAUTION LABEL ALL WIRES PRIO...

Page 10: ...e safety information above on this page If you do not smell gas go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold i...

Page 11: ...ely call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For com...

Page 12: ...ement on generator Be sure wire connections from generator at gas valve terminals are tight and generator is fully inserted into the pilot bracket One of the wall switch wires may be grounded Remove w...

Page 13: ...niter is sparking at the pilot assembly when the ON OFF switch is activated If not undertake the following steps With ON OFF switch OFF remove wire at TR terminal at the ignition control module Discon...

Page 14: ...ed wall switch Horizontal Trim Installation There are two 2 optional horizontal trim kits Models 41HTK PB 41HTK SPB available for use with the GHC Series appliance The 41 HTK SPB kit s trim is solid p...

Page 15: ...M 3 1 1 1 0 6 3 M 3 1 1 e t f e L p o T g o L 1 0 2 3 M 3 1 1 1 0 2 3 M 3 1 1 f t h g i R p o T g o L 1 0 3 3 M 3 1 1 1 0 3 3 M 3 1 1 8 8 3 K S D F B S t i K p o t S r o o D 2 4 6 8 3 0 1 2 4 6 8 3 0...

Page 16: ...18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS MILLIVOLT 10 6 22 24 26 21 20 25 23 2 1 1 3 8 5 4 9 GRD 6500 GHC 6500 26 25 11 12 12 7b 7e 7a 7d 7f 7c...

Page 17: ...d n a l a r u t a N 0 0 5 6 D R G e n a p o r P d n a l a r u t a N o N t r a P y t Q o N t r a P y t Q 1 k c a l B r e v u o L r a B B 7 1 9 6 9 B L 5 2 p o T r a B B 6 0 9 6 9 B L 1 3 r e w o L r e...

Page 18: ...ke changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 We...

Reviews: