background image

Superiorfireplaces.US.com

126718-01_D

47

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. A  10/2015

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and fi rebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and fi rebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 

particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Summary of Contents for DRL4543TEN

Page 1: ...icinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Page 2: ...MADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitr...

Page 3: ...famille soient conscients du danger de br lure encouru Les surfaces de votre foyer deviennent EXTR MEMENT CHAUDES La vitre situ e l avant du foyer atteint des temp ratures EXTR MEMENT LEV ES et peut...

Page 4: ...s viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une bar...

Page 5: ...young children and other at risk individuals out of the room and away from hot surfaces This vented gas fireplace is a sealed combustion gas fireplace de signed for residential applications This firep...

Page 6: ...uard or barrier removed for servicing an appliance must be replaced prior to operating the appliance SAFETY Continued Installation and repair should be done by a qualified service person The appliance...

Page 7: ...NFPA 54 USA or the current CSA B149 1 Installation Code Canada Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 National Fire Protection Associa...

Page 8: ...MONWEALTH OF MASSACHUSETTS Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations installed less than seven 7 feet above the finished grade must comply...

Page 9: ...t Do not locate termination cap and outside air vent where excessive snow or ice build up may occur Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting sy...

Page 10: ...tible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall 33 4 to Face Opening 5 53 1 4 1353 mm 53 1 4 1353 mm 38 965 mm 38 965 mm STUDS MOUNTED FLAT INSIDE OF NAILING FLANGE 15 1 4 387 mm MOUN...

Page 11: ...m 16 1 2 419 mm 8 1 4 210 mm 29 7 8 759 mm 29 7 8 759 mm 3 1 2 89 mm 16 3 8 416 mm 7 1 8 181 mm 1 7 8 48 mm 8 1 4 210 mm 4 1 8 105 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 1 25 mm 1 25 mm 52 1321 m...

Page 12: ...en 10 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In C...

Page 13: ...estops when penetrating ceilings or attic spaces For installation of fireplace at elevations of 4000 feet or greater pay special attention to venting requirement recommendations WARNING Read all instr...

Page 14: ...rate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions about this center Figure 17 page 19 4 Attach the vent...

Page 15: ...he firestop spacer may also be installed over the opening at the interior side of the framing 13 Install the termination SV4 5HTKCT From outside the exterior wall slide the collars of the termination...

Page 16: ...silicone caulking to seal the top and sides of the termination up to the underlayment stucco or masonry wall surface Caulk Caulk NOTE See table 1 for wall thickness ranges when using SV4 5HTKCT termin...

Page 17: ...seal both the inner and outer vent pipe 3 If desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 12 Figure 11 Connecting vent compon...

Page 18: ...op spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 V1 VENTING INSTALLATION Continued V Vertical Minimum Requi...

Page 19: ...Frame the ceiling opening Use a plumb line from the ceil ing above the fireplace to locate the center of the vertical run Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions abo...

Page 20: ...oof flashing over the vent sec tion and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges...

Page 21: ...west discharge opening H H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 26 mm minimum cl...

Page 22: ...OR VENTING KITS AND COMPONENTS Table 3 Listed Components Listed Secure Flex Components Continued F1801 SFKIT36CT Compact Termination for flex with 36 914 mm compressed flex F1802 SFKIT48CT Compact Ter...

Page 23: ...vent 4 Slide the inner flex vent over the adaptor collar at least 1 3 4 5 NOTE Ensure the flex vent is free from damage or tears 6 Slide the gear clamp down and tighten it fully to secure the flexible...

Page 24: ...ified service person must con nect fireplace to gas supply Follow all local codes CAUTION For propane LP units never connect fireplace directly to the propane LP supply This heater requires an externa...

Page 25: ...ply line as shown in Figure 28 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trappe...

Page 26: ...eplace or using compressed air 3 Check all joints from propane LP supply tank or gas meter to equipment shutoff valve see Figure 31 or Figure 32 Apply noncorrosive leak detection fluid to all joints B...

Page 27: ...x using your fingers or the latch opener provided 3 Hook opener over latch as shown in Figure 34 Swing the bot tom of the opener down toward the door You will not need to pull down 4 Tilt open glass d...

Page 28: ...embers to refresh the ember bed during annual maintenance Reinstall the included barrier J7457 WARNING Reinstall any barrier removed before operating the fireplace The barrier is designed to reduce th...

Page 29: ...g Replacing Glass Door page 27 of this manual Installing Access Door Retaining Brackets 1 Screw access door retaining brackets into the inner side face using 2 screws on both the left and right side a...

Page 30: ...use only non combustible materials You may extend up to the edge of the exterior door covering up the screws used for installation Installing Outdoor Barrier F2253 1 Using a flat head screwdriver pop...

Page 31: ...nterrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette...

Page 32: ...nge flamewillalsobepresent Openwindowtoventsmell This will only last a few hours 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch...

Page 33: ...a Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura...

Page 34: ...e entire flame may be blue and will gradually turn yellow orange during the first 15 minutes of operation If the flame remains blue or if the flame is orange with evidence of sooting black tip the air...

Page 35: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 27 Vacuum all glass pieces with a shop vacuum CAUTION Do not vacuum if pieces are hot Use only gl...

Page 36: ...rammed to the Remote Control transmitter To program the module make sure the system has power locate the learn button on left side as shown in Figure 50 Press and release the learn button There will b...

Page 37: ...order above by pressing the MODE Zone or the MODE SET Button MANUAL OFF MODE Transmits flame OFF command LCD Displays MODE Zone OFF is displaye ROOM TEMP Zone Measured temperature is displayed SET TEM...

Page 38: ...OCK icon will appear in the MODE Zone If any touch zone or button is pressed when activated the LCD backlight will illuminate and the LOCK icon will flash for 5 seconds in the MODE Zone SENSOR SAFETY...

Page 39: ...tor 110V MAX 15 AMPS 110V MAX 15 AMPS To Rocker Switch To J Box Pilot Main HI LO DC Motor Drive J7860 Light Module J7865 J7864 J7868 Black Brown Red Orange Orange Green To Ground BATTERY PACK Black Bl...

Page 40: ...y other possible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Parts page 43 7 Checkthatmainpowerisonand...

Page 41: ...nfiguration 1 Air holes at burner inlet blocked 2 Burner flame holes blocked 3 Improper venting or excessive blockage OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combu...

Page 42: ...2 3 1 4 4 5 7 8 9 10 12 13 14 15 16 18 17 19 20 11 6 4 4 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Rep...

Page 43: ...11 J7852 Flextube 1 12 J7853 Burner Gasket 2 13 J7854 Power Module 1 14 J7855 Battery Backup 1 15 J7856 Battery Backup Bracket 1 16 J7857 Valve Bracket 1 17 J7858 Valve NG 1 J7859 Valve LP 1 18 J7860...

Page 44: ...Superiorfireplaces US com 126718 01_D 44 1 2 3 6 7 7 9 4 12 11 14 13 10 15 8 5 16 17 18 19 21 20 PARTS MODELS DRL4543TEN AND DRL4543TEP...

Page 45: ...ng Bracket 2 11 J7883 Ceramic Door Assembly 1 12 J7884 Cover Assembly Mesh Linear DV 1 13 J7885 Corner Bracket 4 14 J7886 Side Walls 2 15 J7887 Pebble Pan 1 16 J7888 Rear Wall 1 17 J7889 Rail Barrier...

Page 46: ...ville TN 37210 Visit us at Superiorfireplaces US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat pro...

Page 47: ...urn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a f...

Page 48: ...ealer name P126718 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Reviews: