background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

14

Figure 43

HOUSE
WIRING

COVER PLATE
Replace Cover Plate
After Electrical
Hook-Up

POWER TO THE FIREPLACE
The Optional Blower Kit
Operates on 115 volt 60 Hz
150 watts AC

GROUND
WIRE

House Wiring Must Be Secured
With The Appropriate Electrical
Connector To The Fireplace
Convenience Outlet Wiring

Measure height to the ceiling from the top of
fireplace-dimension “B.” Use the appropriate
Offset Elevation Chart to find dimension “A.”
Mark point where you will drive your nail to
show the center point for your offset ceiling cut.

Step 2.

 Proceed by using the Straight Up Instal-

lation Instructions for cutting and framing ceil-
ing and roof openings.

Note:

 See Framing and Dimension Chart for the

sizes of the ceiling and roof openings. The size
of the roof opening varies with the degree of
pitch of the roof.

Offset Elbow Assembly

Offset elbows install the same as chimney
sections. First, snap the inner section INTO the
preceding inner section of flue. Check connec-
tion by pulling up slightly to ensure a tight fit.
Next, the outer sections snap lock OVER the
preceding outer section of chimney. Again,
check outer section by pulling up slightly to
ensure proper connection is made.

Return Elbow Assembly

Return elbows install the same way as round
terminations and stabilizers:

Step 1.

 Hold return elbow over top of last

chimney section.

Step 2.

 Center inner slip section into inner flue

pipe-slip down.

Step 3.

 Center outer-locking section over outer

chimney pipe. Push down until locking joint has
firmly engaged.

Step 4.

 Pull up slightly on return elbow to

ensure locking joint has firmly engaged.

Step 5.

 Secure support straps to framing

members by nailing under tension in sheer
(

Figure 42 ).

Figure 39

Figure 40

Figure 41

Chimney

Section

Joints

No. 8 x 1/2" SMS

Screws Required At

Ever

y Joint Past 6'

No Screws Required In

Joints For First 6' of Offset

4'

6'

Underside Of Chimney

Chimney Section (S)

FTF8-E30 Return Elbow*

FTF8-30 Offset Elbow*

B

A

*Part of Offset/Return Package Model FTF8-ES30

Return

Elbow

Note:

 The return elbow assembly performs the

same function as a stabilizer. Consider this
when determining the need for a stabilizer.

Note:

 Do not apply excessive pressure to any

subsequent chimney section following return
elbow assembly when installing. Ensure that
each subsequent chimney section is securely
attached by testing as noted above.

OPTIONAL EQUIPMENT
CONSIDERATIONS

Blower Kits (Circulating Models Only)

Blower Kits model FBK-100/200 are available
for use with circulating models.  The Blower
Kit can be installed prior to or after installation
of the fireplace.

When installing the FBK-100 Blower Kit, a
Blower Switch Kit (Model FUBSK) is required.
This switch kit allows for a unit mounted
blower switch to be used.  The FUBSK is not
included and must be purchased separately.

The FBK-200 Blower Kit comes standard with
a wall mounted variable speed control switch.

Note:

  The fireplace must have provisions for

a wall mounted On/Off switch in order to install
the FBK-200.

THE FIREPLACE MUST BE WIRED TO THE
HOUSE ELECTRICAL SYSTEM AT THE TIME
OF INSTALLATION IN ORDER FOR THE OP-
TIONAL FANS TO OPERATE, (SEE 

FIGURES

43 AND 44 ).

Note:

  The utilization of fans will increase the

air flow around the firebox.  However, only a
minimal increase in heat output should be
anticipated.

INSTALLING OFFSETS

First, review the Offset Elevation Chart and
Figure 41 for reference.

Step 1.

 Determine the offset distance where

chimney is to pass through the first ceiling-
dimension “A.” To find this point on your
ceiling, first determine the center point for a
vertical chimney following the instructions for
vertical installation.

Figure 42

Summary of Contents for BC-42

Page 1: ...r or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories...

Page 2: ...hysical damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your d...

Page 3: ...11 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUniformBuildingCodes When complete these fireplace systems con sists of five basic sub systems 1...

Page 4: ...ermal Barrier 8 Level Chase Enclosure A chase is a vertical box like structure con structedtosurroundthefireplaceandchimney Refer to Figure 2 for a typical chase configura tion As with all chimney ins...

Page 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Page 6: ...surface If a wall covering such as drywall is to be attached to the rear wall then the 20 524 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance...

Page 7: ...Shown FOAK Combustion Air Kit Optional Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will...

Page 8: ...nsions In new construction to determine chimney cen terline useplumblinefromrooforceilingabove fireplace to center of flue collar on fireplace For remodeling plumb to center of flue collar from ceilin...

Page 9: ...ign which ensures an immediate tight assembly between sections Plan your chimney require ments carefully before assembly as chimney is difficult to disassemble after installation If disassembled the t...

Page 10: ...ht dam age the chimney section refer to Figure 32 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to locking band assembly extend and...

Page 11: ...Thetopofthechimneymustbeatleast2 above this reference point In all cases the chimney cannotbelessthen3 abovetheroofattheedge of the chimney The 2 in 10 rule is necessary in the interest of safety but...

Page 12: ...374 31 2 0 1 1 7 380 31 8 1 0 0 8 Step 2 Use Height of Chimney Only column in The Vertical Elevation Chart to determine combinations of chimney used above return elbow to achieve desired heights Refer...

Page 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Page 14: ...ection Joints No 8 x 1 2 SMS S c r e w s R e q u i r e d A t E v e r y J o i n t P a s t 6 N o S c r e w s R e q u i r e d I n J o i n t s F o r F i r s t 6 o f O f f s e t 4 6 Underside Of Chimney Ch...

Page 15: ...ck all connections with soap suds leaks will bubble Never test any gas line con nection with a match or open flame This provision is intended for connection to a decorative gas appliance incorporating...

Page 16: ...of millboard or a du rable noncombustiblematerialhavinganequal or greater insulating value than K 54BTU IN FT2 HR F At no time may a perpendicular side wall be positioned closer than 9 inches Figure...

Page 17: ...R values are used to determine acceptable combinations of materi als because R values are additive where r and k values are not Hearth Extension Dimensions A 16 B 35 C 8 D 51 A B D C C R value 1 r x...

Page 18: ...um of all R values is 70 10 068 10 968 This would not be an acceptable combination of material for the hearth extension since the total calculated R value of the materials used is under the required R...

Page 19: ...63L42 FTF8 CTD Chase Termination Square 63L48 FTF8 CT1 Chase Termination Round 63L45 FTF8 CTDT Chase Termination Square 63L51 FTF8 CT2 Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed...

Page 20: ...M REV C 11 2003 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...

Reviews: