background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

2

TABLE OF CONTENTS

Safety Rules .................................... page 2

Tools and Building Supplies ............ page

2

Precautions ..................................... page

3

Introduction ..................................... page

3

Clearances/Height Requirements ..... page

3

Chimney System ............................. page

3

Assembly Outline ............................. page

4

Location of Fireplace ....................... page

4

Assembly Steps ............................... page

5

Preinstallation Notes ........................ page

5

Clearances ....................................... page

5

Installing the Fireplace ..................... page

5

Fireplace Specifications .................. page 6

Framing Specifications .................... page 7

Installing the Chimney System ........ page

8

30

°

 Offset through Floor/Ceiling ...... page

9

Ten Foot Rule Summary .................. page 11

Multiple Terminations ...................... page 11

Chimney Component Calculations ... page 11

Special Offset Instructions ............... page 12

Offset Calculations ........................... page 12

Vertical Elevation Chart ................... page 12

Offset Elevation Chart ..................... page 13

Installing Offsets .............................. page 14

Optional Equipment Considerations . page 14

Forced Air Kits ................................. page 14

Combustion Air Kits ........................ page 15

Gas Line Connection ........................ page 15

Vent Free Appliances ....................... page 15

Glass Doors ..................................... page 16

Cold Climate Insulation .................... page 16

Fireplace Finishes ............................ page 16

Mantels and Trim ............................. page 16

Hearth Extensions/Wall Shields ....... page 16

Finish Requirements ........................ page 18

Installation Components .................. page 18

IMPORTANT: PLEASE READ AND
UNDERSTAND THESE RULES TO
FOLLOW FOR SAFETY.

1.

 Before starting your fireplace installation,

read these installation instructions carefully to
be sure you understand them completely and in
entirety. Failure to follow them could cause a
fireplace malfunction resulting in serious injury
and/or property damage.

The manufacturer is not responsible for any
smoking or related problems that may result
from the lack of adequate combustion air. It is
the responsibility of the builder/contractor to
ensure that adequate combustion air has been
provided for the fireplace.

13.

 DO NOT use a fireplace insert or any other

products not specified herein by the manufac-
turer for use with this fireplace. All gas log sets
must be operated with the damper clamped
open, including unlisted “vent free” log sets.
Listed “vent-free” log sets may be operated
with the damper closed.

14.

 "Smoke free” operation is not warranteed

nor are we responsible for inadequate system
draft caused by mechanical systems, general
construction conditions, inadequate chimney
heights, adverse wind conditions and/or un-
usual environmental factors or conditions be-
yond our control.

15.

 Never, under any circumstances, install a

fireplace, chimney component or any acces-
sories, that has visible or suspected physical
damage as a result of handling or transporta-
tion. These items should be inspected by your
distributor or qualified factory representative
to ensure safe condition. When in doubt, con-
sult your distributor.

16.

 For additional safety considerations and

complete operating instructions, refer to the
Care and Operation Manual provided with the
fireplace.

TOOLS AND BUILDING SUPPLIES
NORMALLY REQUIRED

Tools should Include:

Phillips screwdriver
Hammer
Saw and/or sabersaw
Level
Measuring tape
Plumb line
Electric drill and bits
Pliers
Square

Building supplies:

Framing materials
Wall finishing materials
Caulking materials (noncombustible)
Fireplace surround and hearth
extension materials (noncombustible)

2.

 Always check your local building codes. The

installation must comply with all local, regional,
state and national codes and regulations.

3.

 These fireplaces must be installed with

Security Chimneys FTF8 (8" inside diameter)
Chimney System only. These systems are in-
tended for use in any application where a
traditional masonry type fireplace would ap-
ply. The chimney system must always vent to
the outside of the building.

4.

 To ensure a safe fireplace system and to

prevent the build-up of soot and creosote,
inspect and clean the fireplace and chimney
prior to use and periodically during the heating
season.

5.

 Use solid fuel only. DO NOT use artificial

wax based logs, chemical chimney cleaners or
flame colorants in your fireplace.

6.

 DO NOT use charcoal or coal under any

circumstances.

7.

 NEVER use gasoline, gasoline-type lantern

fuel, kerosene, charcoal lighter fluid, or similar
liquids to start or “freshen up” a fire in this
fireplace. Keep any flammable liquids a safe
distance from the fireplace.

8.

 NEVER leave children unattended when

there is a fire burning in the fireplace.

9.

 Always keep flue damper open when heat is

present in the fireplace.

10.

 Before servicing, allow the fireplace to

cool. Always shut off any electricity or gas to
the fireplace while working on it. This will
prevent any possible electrical shock or burns.

11.

 This fireplace is not intended to heat an

entire home or be used as a primary heat
source. It is designed to ensure homeowner
comfort by providing supplemental heat to the
room.

12.

 Always ensure an that adequate supply of

replacement combustion air from the outside
of the house is accessible to the fire to support
normal combustion. Fireplaces consume large
volumes of air during the normal combustion
process. In the event the home is tightly sealed
with modern energy efficient features, the op-
tional combustion air kit may not provide all
the air required to support combustion.

Summary of Contents for BC-42

Page 1: ...r or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories...

Page 2: ...hysical damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your d...

Page 3: ...11 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUniformBuildingCodes When complete these fireplace systems con sists of five basic sub systems 1...

Page 4: ...ermal Barrier 8 Level Chase Enclosure A chase is a vertical box like structure con structedtosurroundthefireplaceandchimney Refer to Figure 2 for a typical chase configura tion As with all chimney ins...

Page 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Page 6: ...surface If a wall covering such as drywall is to be attached to the rear wall then the 20 524 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance...

Page 7: ...Shown FOAK Combustion Air Kit Optional Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will...

Page 8: ...nsions In new construction to determine chimney cen terline useplumblinefromrooforceilingabove fireplace to center of flue collar on fireplace For remodeling plumb to center of flue collar from ceilin...

Page 9: ...ign which ensures an immediate tight assembly between sections Plan your chimney require ments carefully before assembly as chimney is difficult to disassemble after installation If disassembled the t...

Page 10: ...ht dam age the chimney section refer to Figure 32 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to locking band assembly extend and...

Page 11: ...Thetopofthechimneymustbeatleast2 above this reference point In all cases the chimney cannotbelessthen3 abovetheroofattheedge of the chimney The 2 in 10 rule is necessary in the interest of safety but...

Page 12: ...374 31 2 0 1 1 7 380 31 8 1 0 0 8 Step 2 Use Height of Chimney Only column in The Vertical Elevation Chart to determine combinations of chimney used above return elbow to achieve desired heights Refer...

Page 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Page 14: ...ection Joints No 8 x 1 2 SMS S c r e w s R e q u i r e d A t E v e r y J o i n t P a s t 6 N o S c r e w s R e q u i r e d I n J o i n t s F o r F i r s t 6 o f O f f s e t 4 6 Underside Of Chimney Ch...

Page 15: ...ck all connections with soap suds leaks will bubble Never test any gas line con nection with a match or open flame This provision is intended for connection to a decorative gas appliance incorporating...

Page 16: ...of millboard or a du rable noncombustiblematerialhavinganequal or greater insulating value than K 54BTU IN FT2 HR F At no time may a perpendicular side wall be positioned closer than 9 inches Figure...

Page 17: ...R values are used to determine acceptable combinations of materi als because R values are additive where r and k values are not Hearth Extension Dimensions A 16 B 35 C 8 D 51 A B D C C R value 1 r x...

Page 18: ...um of all R values is 70 10 068 10 968 This would not be an acceptable combination of material for the hearth extension since the total calculated R value of the materials used is under the required R...

Page 19: ...63L42 FTF8 CTD Chase Termination Square 63L48 FTF8 CT1 Chase Termination Round 63L45 FTF8 CTDT Chase Termination Square 63L51 FTF8 CT2 Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed...

Page 20: ...M REV C 11 2003 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...