Superior BBV-36REN Installation Instructions Manual Download Page 3

3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance
and have it serviced by a qualified profes-
sional, as it may not be operating correctly.

WARNING:  B-VENT APPLIANCES ARE
NOT DESIGNED TO OPERATE IN NEGA-
TIVELY PRESSURED ENVIRONMENTS
(PRESSURE WITHIN THE HOME IS LESS
THAN PRESSURES OUTSIDE). SIGNIFI-
CANT NEGATIVELY PRESSURED ENVI-
RONMENTS CAUSED BY WEATHER,
HOME DESIGN, OR OTHER DEVICES MAY
IMPACT THE OPERATION OF THESE AP-
PLIANCES.  NEGATIVE PRESSURES MAY
RESULT IN POOR FLAME APPEARANCE,
SOOTING, DAMAGE TO PROPERTY AND/
OR SEVERE PERSONAL INJURY. DO NOT
OPERATE THESE APPLIANCES IN NEGA-
TIVELY PRESSURED ENVIRONMENTS.

WARNING:  FAILURE TO COMPLY
WITH THE INSTALLATION AND OPER-
ATING INSTRUCTIONS PROVIDED IN
THIS DOCUMENT WILL RESULT IN AN
IMPROPERLY INSTALLED AND OPER-
ATING APPLIANCE, VOIDING ITS WAR-
RANTY.  ANY CHANGE TO THIS APPLI-
ANCE AND/OR ITS OPERATING CON-
TROLS IS DANGEROUS.  IMPROPER
INSTALLATION OR USE OF THIS AP-
PLIANCE CAN CAUSE SERIOUS IN-
JURY OR DEATH FORM FIRE, BURNS,
EXPLOSION OR CARBON MONOXIDE
POISONING.

WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZ-
ARDS OF HIGH SURFACE TEMPERA-
TURES. USE CAUTION AROUND THE
APPLIANCE TO AVOID BURNS OR
CLOTHING IGNITION. YOUNG CHIL-
DREN SHOULD BE CAREFULLY SUPER-
VISED WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.

WARNING:  DO NOT PLACE CLOTH-
ING OR OTHER FLAMMABLE MATE-
RIALS ON OR NEAR THIS APPLIANCE.

AVERTISSEMENT: SURVEILLER LES
ENFANTS.  GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.

WARNING:  THIS APPLIANCE MAY ONLY
BE FITTED WITH DOORS CERTIFIED
FOR USE WITH THE APPLIANCE.

AVERTISSEMENT: POUR UTILISATION
UNIQUEMENT AVEC LES PORTES EN
VERRE CERTIFIÊES AVEC L'APPAREIL.

These appliances are equipped with an inte-
gral combustion air door and actuator arm.
Combustion air kits are optional and must be
installed before removing the securing screw
allowing the movement of the combustion air
actuator arm 

(see Step 7).

LOCATION

Typical Locations

Figure 1

In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to
the exterior and access to the fuel supply are
also important. Due to high temperatures the
appliance should be located out of traffic and
away from furniture and draperies. Consider-
ation should be given to traffic ways, furni-
ture, draperies, etc., due to elevated surface
temperatures. The location should also be
free of electrical, plumbing or other heating/
air conditioning ducting.

The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materi-
als. However, if installed on combustible ma-
terials, such as carpeting, vinyl tile, etc., a
metal or wood barrier covering the entire bot-
tom surface must be used.

These appliances may be used for bedroom
installations in the United States and are listed
accordingly.  These units may not be in-
stalled in bedrooms in Canada.

CLEARANCES

Minimum clearance to combustibles for the
appliance is as follows: sides and back - 0" (0
mm), floor - 0" (0 mm), adjacent wall - 0" (0
mm), ceiling - 64" (1625 mm).

Millivolt appliances may be fitted at time of
manufacture with either a Honeywell millivolt
gas control valve or as SIT millivolt gas control
valve.  Both valves have been tested with and
approved for use with these appliances and are
listed accordingly.

Test gage connections are provided on the
front of the millivolt gas control valve (identi-
fied IN for the inlet and OUT for the manifold
side).  A 

¹⁄₈

" NPT test gage connection is

provided at the inlet and outlet side of
the electronic gas control valve.

Minimum inlet gas pressure to the appliance is
5.0 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.

Maximum inlet gas supply pressure to the
appliance is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.

The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure test-
ing of the gas supply piping system at test
pressures equal to or less than 

¹⁄₂

 psig (3.5 kPa).

The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 

¹⁄₂

 psig

(3.5 kPa).

These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.

Do not place clothing or other materials on or
near this appliance.

Summary of Contents for BBV-36REN

Page 1: ...S CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de g...

Page 2: ...mperative that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean S assurerquelebr leuretlecompartimentdes commandes sont propres Voir les instruc tions d installa...

Page 3: ...r vent system routing to the exterior and access to the fuel supply are also important Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Con...

Page 4: ...t appliances provided that there is at least 2 ft 0 6m between the proximal edges of the vent caps These appliances may be vented adjacent to a chimney vent servicing a solid fuel fireplace provided t...

Page 5: ...ENCE The typical sequence of installation follows however eachinstallationisuniqueresultingin variations to those described 1 Construct the appliance framing 2 Route gas supply line to appliance locat...

Page 6: ...d specifications on pages 4 and 5 for framing dimensions and details Framing header may be positioned di rectly on the fireplace top spacers Step 4 Install the Vent System and Exterior Termination A C...

Page 7: ...ensure proper operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework The gas control valve is located in the lower control compartment...

Page 8: ...hen push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening Operate the actuator through several cycles including the...

Page 9: ...for the line to purge itself of air Once purging is complete the pilot and burner will light and operate as indicated in the in struction manual Subsequent lightings of the appliance will not require...

Page 10: ...ombustible mantel shelf projecting a maximum of 12 305 mm from the wall and which must be installed a minimum distance of 14 368 mm from the top of the firebox opening Orifice Air Shutter Burner Tube...

Page 11: ...r the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Figure 24 64 1626 mm Min to Ceiling 14 Min...

Page 12: ...e available to adapt your appliance from the use of one type of gas to the use of another These kits contain all the neces sary components needed to complete the task including labeling that must be a...

Page 13: ...ner clip andcarefullyremovetheignitorassembly Exercise extreme care to prevent damage to or breakage of the ignitor assembly Remove the screw securing the pilot assembly to its mounting bracket Back o...

Page 14: ...14 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 16: ...00 000M REV H 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Reviews: