background image

13

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Step 6.  All Millivolt Systems – Attach ma-
nometer to the manifold side pressure test
fitting and verify manifold pressure reads 3.5
inches water column (0.87 kPa) for natural
gas, and 10.0 inches water column (2.49 kPa)
for propane gas.

Step 7.  Refer to 

Figure 27  and remove the

pilot hood assembly to access the hexed pilot
orifice.  Remove and replace the orifice with
the one provided with the kit.

Figure 28

Figure 29

Figure 30

When reinstalling the ignitor assembly, use
extreme care to prevent damage and break-
age.  Do not apply any leverage to the ignitor
assembly while restoring the retainer clip to
its original position
.

All Models

Step 9.  Unscrew the orifice from the manifold
and replace it with the one provided with the
kit, #42 (0.0935) for natural gas units and
(0.058) for propane 

(see Figure 30 ).

Figure 31

Step 12. Turn on gas supply and test for gas
leaks.

Step 10. Reassemble all removed compo-
nents by reversing the procedures outlined in
the preceding steps.  Use pipe joint compound
or Teflon tape on all pipe fittings before install-
ing (ensure propane resistant compounds are
used in propane applications, do not use pipe
joint compounds on flare fittings).

Step 11. Attach apropriate conversion kit
label 

(see Figure 31 ) to the rating plate on

the appliance.

See 

Figure 28 and replace the pilot orifice as

follows:  Remove the ignitor assembly retainer
clip, and carefully remove the ignitor assembly.
Exercise extreme care to prevent damage to
or breakage of the ignitor assembly
.  Remove
the screw securing the pilot assembly to its
mounting bracket.  Back off the flare nut at the
end of the pilot gas line to free the pilot assem-
bly from the gas line.  Remove the pilot orifice
and replace it with the one provided with the
conversion kit.  Reinstall the pilot assembly by
reversing the steps detailed here.

Note:  If the ignitor assembly is damaged, a replacement kit is available, order Catalog Number 87L54.

Retaining
Clip

Ignitor
Assembly

Pilot
Assembly

Pilot
Orifice

Flare Nut

THIS APPLIANCE HAS BEEN CONVERTED TO:

NATURAL GAS

INPUT BTU/HR  –  24,000

MANIFOLD PRESSURE  –  3.5"

ORIFICE SIZE  –  #42 (0.0935)

THIS APPLIANCE HAS BEEN CONVERTED TO:

PROPANE/LPG

INPUT BTU/HR  –  24,000

MANIFOLD PRESSURE  –  10"

ORIFICE SIZE  –  (0.058)

Spring

Adjusting
Screw

Slotted
Cap

P

S

I

OFF

I

ON

CONTROL

IG

N

IT

E

Manifold
Pressure
Test Port

Inlet Pressure Test Port

Figure 27

Pilot
Orifice

Electronic Appliances

Step 8.  Honeywell Electronic Valves - See
Figure 29  and the instructions provided with
the kit.  Remove the slotted cap screw, o-ring,
pressure-regulating adjusting screw and
spring.  Retain all parts for possible later use.
Install new components from the kit.  Black
cap and red spring for propane gas units.
Silver cap and stainless steel spring fro natural
gas units.  Before installing the cap, attach
manometer to the manifold side pressure test
fitting and adjust screw until pressure reads
3.5 inches water column (0.87 kPa) for natural
gas, and 10.0 inches water column (2.49 kPa)
for propane gas.

Summary of Contents for BBV-36REN

Page 1: ...S CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de g...

Page 2: ...mperative that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean S assurerquelebr leuretlecompartimentdes commandes sont propres Voir les instruc tions d installa...

Page 3: ...r vent system routing to the exterior and access to the fuel supply are also important Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Con...

Page 4: ...t appliances provided that there is at least 2 ft 0 6m between the proximal edges of the vent caps These appliances may be vented adjacent to a chimney vent servicing a solid fuel fireplace provided t...

Page 5: ...ENCE The typical sequence of installation follows however eachinstallationisuniqueresultingin variations to those described 1 Construct the appliance framing 2 Route gas supply line to appliance locat...

Page 6: ...d specifications on pages 4 and 5 for framing dimensions and details Framing header may be positioned di rectly on the fireplace top spacers Step 4 Install the Vent System and Exterior Termination A C...

Page 7: ...ensure proper operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework The gas control valve is located in the lower control compartment...

Page 8: ...hen push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening Operate the actuator through several cycles including the...

Page 9: ...for the line to purge itself of air Once purging is complete the pilot and burner will light and operate as indicated in the in struction manual Subsequent lightings of the appliance will not require...

Page 10: ...ombustible mantel shelf projecting a maximum of 12 305 mm from the wall and which must be installed a minimum distance of 14 368 mm from the top of the firebox opening Orifice Air Shutter Burner Tube...

Page 11: ...r the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Figure 24 64 1626 mm Min to Ceiling 14 Min...

Page 12: ...e available to adapt your appliance from the use of one type of gas to the use of another These kits contain all the neces sary components needed to complete the task including labeling that must be a...

Page 13: ...ner clip andcarefullyremovetheignitorassembly Exercise extreme care to prevent damage to or breakage of the ignitor assembly Remove the screw securing the pilot assembly to its mounting bracket Back o...

Page 14: ...14 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 16: ...00 000M REV H 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Reviews: