background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

INSTALLATION
INSTRUCTIONS

STANDARD SERIES

36" B-VENTED GAS APPLIANCES
P/N  700,000M  REV.  H  07/2004

Millivolt Models

Electronic Models

BBV-36RMN

BBV-36REN

BBV-36RMP

BBV-36REP

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WH Report No. J99025850

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

MODELS

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes. This appliance is
only for use with the type of gas indicated on
the rating plate. This appliance is not convert-
ible for use with other gases, unless a certi-
fied kit is used.

Summary of Contents for BBV-36REN

Page 1: ...S CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de g...

Page 2: ...mperative that the control compartment burners and circulating airpassagewaysoftheappliancebekeptclean S assurerquelebr leuretlecompartimentdes commandes sont propres Voir les instruc tions d installa...

Page 3: ...r vent system routing to the exterior and access to the fuel supply are also important Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Con...

Page 4: ...t appliances provided that there is at least 2 ft 0 6m between the proximal edges of the vent caps These appliances may be vented adjacent to a chimney vent servicing a solid fuel fireplace provided t...

Page 5: ...ENCE The typical sequence of installation follows however eachinstallationisuniqueresultingin variations to those described 1 Construct the appliance framing 2 Route gas supply line to appliance locat...

Page 6: ...d specifications on pages 4 and 5 for framing dimensions and details Framing header may be positioned di rectly on the fireplace top spacers Step 4 Install the Vent System and Exterior Termination A C...

Page 7: ...ensure proper operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework The gas control valve is located in the lower control compartment...

Page 8: ...hen push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening Operate the actuator through several cycles including the...

Page 9: ...for the line to purge itself of air Once purging is complete the pilot and burner will light and operate as indicated in the in struction manual Subsequent lightings of the appliance will not require...

Page 10: ...ombustible mantel shelf projecting a maximum of 12 305 mm from the wall and which must be installed a minimum distance of 14 368 mm from the top of the firebox opening Orifice Air Shutter Burner Tube...

Page 11: ...r the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Figure 24 64 1626 mm Min to Ceiling 14 Min...

Page 12: ...e available to adapt your appliance from the use of one type of gas to the use of another These kits contain all the neces sary components needed to complete the task including labeling that must be a...

Page 13: ...ner clip andcarefullyremovetheignitorassembly Exercise extreme care to prevent damage to or breakage of the ignitor assembly Remove the screw securing the pilot assembly to its mounting bracket Back o...

Page 14: ...14 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Page 16: ...00 000M REV H 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Reviews: