Superior B-500CEN Homeowner'S Care And Operation Instructions Manual Download Page 18

18

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

See Below.

Disconnect the two black wires from the wire nuts. Test switch(s) for
continuity with a multimeter. If continuity is not indicated, switch(s) is
defective and must be replaced.

Note:

 

Before replacing “OFF/ON” switch, be sure to check wiring for loose

connections or broken wires and repair as needed.

Reset the limit switch button.  If still not working, access the leads attached to
the limit switch and check for continuity. If no continuity, replace limit switch.

Check main burner orifice(s) for stoppage. Clean or replace.

Check vent system for obstructions.

A.

Faulty Valve System.

B.

“OFF/ON” or wall switch
defective.

C.

  Faulty limit switch

A.

Burner orifice plugged.

B.

Obstructed vent system.

1.

Burner will not light.

2.

Burners come “ON” but
go “OFF.”

N

ote:

 Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in

the “ON” position.

Important:

 Valve system troubleshooting should only be accomplished by a qualified service technician.

• Turn Off Gas Supply
• Assure Valve Switch Is In ON Position
• Disconnect Control Harness
• Set Thermostat To Call For Heat

• Check For Proper Voltage At Control Harness
  (See Insert A).  Voltage Should Be 24V
  Between Thermostat Or Pressure Switch
  And 24V Common And 24V Hot.

• Line Voltage Power
• Low Voltage Transformer
• Limit Controller
• Thermostat
• Wiring

2

CHECK

START

NO

• Plug Control Harness Into Valve.  Wait For
   Internal Check Delay.

YES

• Igniter Warms Up And Glows Red.

• With Pilot Burner Cable Connected, Measure
   Voltage At Valve HSI Element Output.  24V
   Nominal.  (See Insert B)

NO

• Replace Igniter/Flame Rod Assembly.

YES

• Replace Valve.

NO

• Turn On Gas Supply.    • Pilot Burner Lights.

• Check That Pilot Gas Is Flowing.  Wait To
   Assure Plot Gas Tubing Is Purged.  Recycle
   Call For Heat If Necessary.

NO

YES

NO

YES

YES

1

• Measure Voltage Between 24V Hot And 24V Common
  Leads To Valve Control.  Must Measure At Least 19.5
  VAC With Igniter Powered (See Insert A).  To Identify
  Proper Lead, This Check Must Be Done With The
  Valve Control Connected And Igniter Powered.

• Check Transformer And
   Line Volt Supply.

NO

• Replace Pilot Assembly.

YES

• Check That Pilot Flame Makes Good Contact With
   Pilot Burner Flame Rod.
• Check For Good Electrical Connection Through The
   Pilot Tubing.
• If Both Of The Above Are Good, Replace Igniter/Flame
   Rod Assembly.

• Cycle Thermostat Off And Back On.

YES

• Main Valve Opens And Main Burner Lights.

NO

YES

• System Is Okay.

YES

• Main Burner Lights.

NO

2

1

Igniter Will Cycle Off And Back On Once During
The 90 Second Ignition Trial.  All Voltage
Measurements Must Be Taken While The Igniter
Is Powered.

When Measured Voltage At Connections, Use
Care To Assure Terminals Are Not Damaged.

• Replace Valve.

• Replace Valve.

24 Volt Hot

End View Of
Control Harness
Connector

24 Volt
Common

24 Volt
Switched

Check For Damaged Or Missing Terminals
In Connector

Insert A

Igniter Terminals

Insert B

2

1

f i r e - p a r t s . c o m

Summary of Contents for B-500CEN

Page 1: ...e gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm...

Page 2: ...page 17 Troubleshooting Guide Electronic page 18 Replacement Parts List page 19 Maximum manifold pressure is 3 5 in w c 0 87 kPa for natural gas and 10 in w c 2 49 kPa for LP Propane gas The following...

Page 3: ...t the ON OFF rocker switch will control the appliance ON OFF operation To operate Toggle the switch between its ON and OFF positions OPERATION AND CARE OF YOUR APPLIANCE Appliance operation may be con...

Page 4: ...t least twice a year Morefrequentcleaningmayberequireddueto excessive lint from carpeting bedding materi als etc It is important that control compart ments burners and circulating air passage ways of...

Page 5: ...dges of the glass door 6 If the smoke is not drawn towards the edges of the glass door turn off the appli ance and call a qualified service technican Outside Air Control Lever Outside Air Control Leve...

Page 6: ...nd verify the flame pattern and height displayed by the appli ance conforms to the picture Flames must not impinge on the logs Refer to Figure 9 SIT Millivolt Figure 10 Honeywell Millivolt or Figure 1...

Page 7: ...E CRACKED OR BROKEN GLASSWITHANYMATERIALSOTHERTHAN THOSE PROVIDED BY THE APPLIANCE MANUFACTURER THE GLASS DOOR OF THIS APPLIANCE MUSTONLYBEREPLACEDASACOMPLETE UNIT AS PROVIDED BY THE MANUFAC TURER DO...

Page 8: ...ght the burner refer to the lighting in structions on pages 13 and 14 for Honeywell and SIT millivolt gas valves ELECTRONIC Proper Flame Adjustment Pilot Nozzle 3 8 To 1 2 Inch 9 mm to 13 mm Ground El...

Page 9: ...NTHEFIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUS TION SOOTING AND POOR FLAME QUALITY WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OF...

Page 10: ...quantity required 6 The installation date of the appliance Honeywell and SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18...

Page 11: ...etric of English units flame indicator and clock Fully programmable the Model RCL T allows for command over nearly all operational and temperature variables using the hand held remote control transmit...

Page 12: ...a P e c a F n a e l C l e d o M t i n U o N o N g o l a t a C o N l e d o M t i K 0 0 5 B 6 7 L 0 8 0 5 5 K P F C 0 0 6 B 7 7 L 0 8 0 6 6 K P F C 0 0 8 B 8 7 L 0 8 0 8 8 K P F C s t i K e m a r F r o...

Page 13: ...control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot ligh...

Page 14: ...Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le serv...

Page 15: ...s appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been u...

Page 16: ...specter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la positi...

Page 17: ...ll on page 8 Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takereadingatthermo pile terminals of gas valve Should read 325 millivolts mini mum with optional wall switc...

Page 18: ...tage Power Low Voltage Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burne...

Page 19: ...4 1 3 4 t i K y l b m e s s A r o t i n g I 4 5 L 7 8 1 4 5 L 7 8 1 o N N O I T P I R C S E D 0 0 5 B 0 0 6 B 0 0 8 B o N t r a P y t Q o N t r a P y t Q o N t r a P y t Q y l b m e s s A e c a l p e...

Page 20: ...design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 REPLAC...

Reviews: