NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.

When lighting the appliance, follow these instructions
exactly.

B. BEFORE OPERATING

 smell all around the appliance area

for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

FOR YOUR SAFETY READ BEFORE LIGHTING

Immediately call your gas supplier from a neighbor’s
phone.

If your gas supplier cannot be reached, call the fire
department.

C.

 Use only your hand to turn the gas control lever. Never

use tools. If the lever will not turn by hand, do not try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or an explosion.

D.

 Do not use this appliance if any part has been under

water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.

LIGHTING INSTRUCTIONS — ELECTRONIC

1.

For complete shut-down, turn remote wall switch to
“OFF.”

2.

Open lower control compartment door.

3.

Turn the ON/OFF switch to “OFF”. Do not force.

4.

Close the main line shut-off valve.

5.

Close lower control compartment door.

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

1. STOP!

 Read the safety information above on this page.

2.

Turn remote wall switch to “OFF.”

3.

Open lower control compartment door.

4.

Verify main line shut-off valve is open.

5.

Turn the ON/OFF switch to “OFF”.  Do not force.

6. 

 Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.

7.

Turn the ON/OFF switch to “ON”.  Do not force.

8.

Turn “ON” all electrical power to appliance (remote wall
switch).

9.

Close lower control compartment door.

TO SHUT OFF

1.

Turn off all electrical power to the appliance (remote wall
switch).

ON/OFF Switch

OFF

IN

P

S

I

ON

CONTROL

IG
N

IT
E

R

Front View

f i r e - p a r t s . c o m

Summary of Contents for B-500CEN

Page 1: ...e gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm...

Page 2: ...page 17 Troubleshooting Guide Electronic page 18 Replacement Parts List page 19 Maximum manifold pressure is 3 5 in w c 0 87 kPa for natural gas and 10 in w c 2 49 kPa for LP Propane gas The following...

Page 3: ...t the ON OFF rocker switch will control the appliance ON OFF operation To operate Toggle the switch between its ON and OFF positions OPERATION AND CARE OF YOUR APPLIANCE Appliance operation may be con...

Page 4: ...t least twice a year Morefrequentcleaningmayberequireddueto excessive lint from carpeting bedding materi als etc It is important that control compart ments burners and circulating air passage ways of...

Page 5: ...dges of the glass door 6 If the smoke is not drawn towards the edges of the glass door turn off the appli ance and call a qualified service technican Outside Air Control Lever Outside Air Control Leve...

Page 6: ...nd verify the flame pattern and height displayed by the appli ance conforms to the picture Flames must not impinge on the logs Refer to Figure 9 SIT Millivolt Figure 10 Honeywell Millivolt or Figure 1...

Page 7: ...E CRACKED OR BROKEN GLASSWITHANYMATERIALSOTHERTHAN THOSE PROVIDED BY THE APPLIANCE MANUFACTURER THE GLASS DOOR OF THIS APPLIANCE MUSTONLYBEREPLACEDASACOMPLETE UNIT AS PROVIDED BY THE MANUFAC TURER DO...

Page 8: ...ght the burner refer to the lighting in structions on pages 13 and 14 for Honeywell and SIT millivolt gas valves ELECTRONIC Proper Flame Adjustment Pilot Nozzle 3 8 To 1 2 Inch 9 mm to 13 mm Ground El...

Page 9: ...NTHEFIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUS TION SOOTING AND POOR FLAME QUALITY WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OF...

Page 10: ...quantity required 6 The installation date of the appliance Honeywell and SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18...

Page 11: ...etric of English units flame indicator and clock Fully programmable the Model RCL T allows for command over nearly all operational and temperature variables using the hand held remote control transmit...

Page 12: ...a P e c a F n a e l C l e d o M t i n U o N o N g o l a t a C o N l e d o M t i K 0 0 5 B 6 7 L 0 8 0 5 5 K P F C 0 0 6 B 7 7 L 0 8 0 6 6 K P F C 0 0 8 B 8 7 L 0 8 0 8 8 K P F C s t i K e m a r F r o...

Page 13: ...control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot ligh...

Page 14: ...Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le serv...

Page 15: ...s appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been u...

Page 16: ...specter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la positi...

Page 17: ...ll on page 8 Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takereadingatthermo pile terminals of gas valve Should read 325 millivolts mini mum with optional wall switc...

Page 18: ...tage Power Low Voltage Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burne...

Page 19: ...4 1 3 4 t i K y l b m e s s A r o t i n g I 4 5 L 7 8 1 4 5 L 7 8 1 o N N O I T P I R C S E D 0 0 5 B 0 0 6 B 0 0 8 B o N t r a P y t Q o N t r a P y t Q o N t r a P y t Q y l b m e s s A e c a l p e...

Page 20: ...design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 REPLAC...

Reviews: