background image

AccuTrak

 VPE-2000

 

 

21 

 
 
 

Warranty 

 

The 

AccuTrak 

VPE-2000  is  warranted  for  1  year  to  be  free  of  manufacturing 

defects  adversely  affecting  performance,  and  unconditionally  for  30  days.  
Should  an  instrument  fail  within  the  1  year  warranty  period,  the  unit  will  be 
repaired  or  replaced  provided  in  the  opinion  of  the  factory,  the  instrument  has 
not been tampered with or abused. If during the first 30 days you are unsatisfied 
for any reason, the unit may be returned for full credit providing it is returned in 

“like new” condition.

 

 
If defective,  return to the factory for repair and re-calibration.   Maximum liability 
of  Superior  Signal  Company,  Inc.  shall  be  limited  to  replacement  of 
unsatisfactory product. 
 
Recommendations and product information are believed to be accurate, but the 
furnishing  of  it  does  not  constitute  the  making  of  a  good  process  warranty  of 
Seller. 
 
Superior  Warrants  that  this  product  conforms  to  the  Product  Description 
contained  in  this  literature.   

Superior  makes  no  other  warranty,  whether 

expressed or implied, including warranties of merchantability or of fitness 
for  a  particular  purpose  or  application.

    No  statements  or  recommendations 

contained  herein  are  to  be  construed  as  inducements  to  infringe  any  relevant 
patent, now or hereafter in existence.  Superior neither assumes nor authorizes 
any  representatives  or  other  person  to  assume  for  it  any  obligation  of  liability 
other than such as expressly set forth herein. 

Under  no  circumstances  shall  Superior  be  liable  for  incidental, 
consequential  or  other  damages  from  any  alleged  negligence,  breach  of 
warranty,  strict  liability  or  any  other  theory,  arising  out  of  the  use  or 
handling of this product.

 

 

 

 

 

 

 

 

 

Summary of Contents for AccuTrak VPE-2000

Page 1: ...Model VPE 2000 User s Manual Superior Signal Company LLC www SuperiorSignal com...

Page 2: ...ptions 10 APPLICATIONS OVERVIEW 11 1 AIRBORNE APPLICATIONS EXTERNAL SOUNDS 11 Leaks 11 Methods of reducing background noise interference 12 Frequency Selection Airborne 13 Recording overall system noi...

Page 3: ...ch accurate readings and consistent results in repeatable tests The internal signal processing is performed by a patented process with additional patents pending This circuitry assures the reduction o...

Page 4: ...nsity display meter Shows relative strength of detected signal in a bargraph format D Power button Turns the instrument on or off E Alphanumeric Display A N D Level Mode Indicator Displays active mode...

Page 5: ...re facing the floor and the sensor is facing away from your body At the opposite end from the sensors the end closest to you there is a sliding panel Apply minimal pressure to the center of the panel...

Page 6: ...sonic is also available and is activated the same way Once activated you will begin to hear a translation of any ultrasonic sound present in test area and the LED bargraph meter will display the stren...

Page 7: ...ing or scraping in bearings 4 The VPE 2000 always defaults back to Sensitivity as the active mode therefore if your readings are off the scale simply press the to reduce the reading to within the rang...

Page 8: ...like motions Inside a tube where a gas may be flowing the flow is normally laminar which means that a given layer of gas does not mix with layers above it or below it This condition happens in a strai...

Page 9: ...VPE 2000 will begin the cycle again Setting the Sensitivity The AccuTrak VPE 2000 always defaults back to sensitivity as the active mode This means that after any other adjustment has been made it wil...

Page 10: ...ws Cont Continuous the A N D will show the level of the signal in real time Peak Peak Hold the A N D will hold the highest reading for 5 seconds Off Turns the alphanumeric display off with the excepti...

Page 11: ...il only the first one or two lights are lit on the LED bargraph meter Check around fittings flanges and all other suspected areas If at anytime the display is at maximum due to background noise in the...

Page 12: ...translation process of the AccuTrak helps you to distinguish the difference between the two signals Practice listening to different components of your system this will help you to identify problems fr...

Page 13: ...mpared to previous and future readings Although the AccuTrak will only record the ultrasonic range of a noisy system which we can t hear this part of the sound will increase in proportion to the sonic...

Page 14: ...effective The sound of most bearings comes alive in the Low range probe however very high speeds and or vibration sometimes make it necessary to use the High frequency probe Your experiences with you...

Page 15: ...y type of valve which may be leaking internally Are valves functioning properly When in the closed position are they truly closed Is the TXV clogged or iced Restrictions or leaks in a valve can cause...

Page 16: ...wear When testing a bearing or other moving machinery it is important to 1 Record your volume sensitivity and frequency range 2 Record the level on the alphanumeric display 3 Record or mark the test...

Page 17: ...nal increased ultrasonic energy This ultrasonic energy is generated from the friction associated with these problems and can be detected with the AccuTrak With experience you will know what readings a...

Page 18: ...f a loose fan belt in a car Early warning of such wear is indicated by a similar sound in the ultrasonic range Ductwork Leaking ducts can be a significant source of energy loss The AccuTrak can be use...

Page 19: ...the repair BEFORE this happens A significant increase in compressor noise indicates looseness wear or other serious problems AccuTrak helps prevent vibration caused leaks Steam is costly to produce ke...

Page 20: ...use excessive pressure on the item being tested Bent probes or cracked sensor housings are considered abuse and will not be covered under warranty Keep the instrument stored in its protective carrying...

Page 21: ...ion are believed to be accurate but the furnishing of it does not constitute the making of a good process warranty of Seller Superior Warrants that this product conforms to the Product Description con...

Page 22: ...probe 13 Leak Detection 5 method outline 5 leaks 10 quantifing 7 Quick Overview 5 modes selection 8 natural gas 7 Operation 8 operational mode 8 Pneumatics and Hydraulics 17 Sensitivity Setting the se...