background image

SuperiorFireplaces.us.com

127055-01_H

20

ACCESSORIES 

Continued

ANTI-DRAFT SHIELD

(Round Top Termination Only)

F0927

ADS-8DM

Anti-Draft Shield for Round Top Only

MESH ROUND TOP TERMINATIONS

F0916

RT-8DM

Round Top with Mesh Screen

F0888

RT-8HT

Hi-Temp Round Top with Mesh Screen

MESH ROUND TOP TERMINATIONS WITH SLIP SECTION

F0917

RTT-8DM

Round Top with Slip Section & Mesh

F0889

RTT-8HT

Hi-Temp Round Top w/Mesh Screen and Slip Section

ROUND TOP TERMINATIONS WITH LOUVERS

F0918

RLT-8DM

Round Top with Louvered Screen

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

ROUND TOP TERMINATIONS WITH LOUVERS W/SLIP SECTION

F0919

RLTT-8DM

Round Top with Slip Section & Louvers

F0891

RLTT-8HT

Hi-Temp Round Top w/Lvrd. Screen and Slip Section

SQUARE TOP TERMINATION WITH LOUVERS

F0920

ET-8DM

Square Top

F0892

ET-8HT

Hi-Temp Pyramid Top with Slip Section

SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION

F0921

ETL-8DM

Square Top with Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top with Slip Section

MESH SQUARE TOP TERMINATION

F0922

ETO-8DM

Square Top with Mesh

MESH SQUARE TOP TERMINATION WITH SLIP SECTION

F0923

ETLO-8DM

Square Top with Mesh and Slip Section

STAINLESS STEEL HOOD

Required when installing a vent-free gas log in this fireplace.

F1053

HS42

42" Stainless Steel Hood w/4" Brow

DRAIN PAN

F1090

DP42

Drain Pan 

FIRESTOP THIMBLE

F0911

38FST

Firestop Thimble ( Use when penetrating a joist)

F0912

FST30

Firestop Thimble ( Use when offsetting through a joist)

LABEL-UL127-50PK

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

900599-01

F2659

LABEL-UL127-

50PK

UL127 Venting Label - 50 PK

Summary of Contents for WRE3042WH

Page 1: ...ADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L au...

Page 2: ...Venting Installation 7 Optional Gas Line Installation 12 Operation and Maintenance Guidelines 13 Replacement Parts 14 Technical Service 14 Important Notices Canada 15 Parts 16 Accessories 18 Draft Sm...

Page 3: ...canposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESU...

Page 4: ...1 1 2 39 mm 46 3 4 1188 mm 22 1 2 572 mm INNER DIA 12 3 8 315 mm 5 8 16 mm 36 915 mm 48 1220 mm OUTER DIA 15 381 mm 24 610 mm 8 204 mm 42 1067 mm 41 1042 mm 48 1067 mm 3 4 19 mm AIR SPACE BACK AND SI...

Page 5: ...s or roof rafters will make installation easier 4 An outside air kit is available with this fireplace see Optional Outside Air Kit on page 7 MINIMUM CLEARANCE TO COMBUSTIBLES Ceiling 40 1016 mm minimu...

Page 6: ...ss marble stone etc Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see Figure 3 WARNING Hea...

Page 7: ...he flue pipe section with the hemmed end up Press down on each pipe section until the lances securely engage the hem on the fireplace starter The wire will assure the proper spac ing between the inner...

Page 8: ...ecurely nailed to rafters or joists see Figure 8 details A and B 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney sys...

Page 9: ...uble wall pipe passes through a framed opening into an attic space the firestop must be placed into an attic floor as shown in Figure 11 NOTICE The installation of a firestop thimble FST30 or 38FST is...

Page 10: ...st roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 13 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on...

Page 11: ...of 10 feet see Figure 17 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top around the fireplace face It is importan...

Page 12: ...to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or c...

Page 13: ...back from the doors and never allow flames to contact the glass WARNING FIREPLACES EQUIPPED WITH GLASS DOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENED OR DOORS FULLY CLOSED DOORS IF LEFT PARTLY...

Page 14: ...through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace...

Page 15: ...all Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT...

Page 16: ...SuperiorFireplaces us com 127055 01_H 16 PARTS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 MODEL CATALOG NO WRE3042WS F0453 WRE3042WH F0454...

Page 17: ...r 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 J4052 Access Panel 1 23 J4513...

Page 18: ...Her White S42 1 4 Refractory Rear Her White S42 1 5 Refractory Btm Rear White S42 1 6 Refractory Btm Frnt White S42 1 1 2 4 3 6 5 Stacked Refractory Shown ACCESSORIES REFRACTORY STAIN KITS Use the re...

Page 19: ...ap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND R...

Page 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Page 21: ...electing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...7055 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: