WARNING
•
Use only a IHP glass doors, specifically designed
for the WCT6840WS fireplace.
•
The fireplace cannot be operated without door or
firescreen. Consult your dealer to select the correct
replacement door or firescreen.
•
Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
2
Figure 7
DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS
IT MAY CAUSE THE PAINT TO PEEL.
CAUTION : DO NOT ALLOW WINDOW CLEANER TO GET IN CONTACT
WITH DOOR GASKET OR PAINT ON FACADE OR DOOR. ONCE CLOSED,
CONTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN
PROVOKE PAINT PEELING OFF.
Gasket Replacement
Remove the doors from the unit (see section
Door Installation)
and lay
them on a clean nonabrasive surface. To replace the gasket, first remove
all of the old gasket and gasket cement. Make sure that the surface is
totally clean before applying new cement (a high temperature silicone
caulking rated at 500° F (260° C), is suitable) or adhesion problems may
result. Apply gasket cement to the gasket channel and install the new
gasket. This replacement part is available from your IHP Dealer in the
following dimensions:
Gasket
Part #
Length
qty
Dimensions
Around the
glass
PR-SR1685C
61-3/4”
(1569 mm)
2
1” width x 3/16” thick
(26 mm x 5 mm)
On the door
frame
PR-SR1823I
48-3/8”
(1229 mm)
2
3/4” diameter
(19 mm)
Between the
doors
PR-SR1823J
17-5/8”
(448 mm)
2
5/8” diameter
(16 mm)
Table 1
1
GLASS CARE
Glass Replacement
The glass used for the WCT6840WS fireplace is a high temperature ceramic
glass (1,400° F). If the glass breaks or cracks, it must be replaced with
an identical ceramic glass. Tempered glass or ordinary glass will not
withstand the high temperatures of the WCT6840WS fireplace. Replace-
ment glass should be purchased from a IHP dealer (see
“Replacement
Parts”
on
Page 22)
.
DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS.
Glass Cleaning
The WCT6840WS fireplace is designed to keep the glass clean under
normal operating conditions. If the WCT6840WS fireplace is operated
continuously with the combustion air controls closed, the glass will tend to
get dirty unless the fuel, firebox and glass are maintained at hot tempera-
tures (see section
Refueling For Best Performance)
. To clean the glass,
there are a number of specially designed cleaners to remove creosote.
Your IHP Dealer can recommend a suitable cleaner. Regular household
glass cleaners will not clean creosote.
Do not use abrasives such as
steel pads, steel wool or oven cleaner as they will scratch the glass.
FIREPLACE INSTALLATION
Locating The WCT6840WS Fireplace
The best location to install your fireplace is determined by considering
the location of windows, doors, and the traffic flow in the room where
the fireplace is located, allowing space in front of the unit for the hearth
extension and the mantel, and taking into consideration the location of
the hot air ducts (optional), outside air kit and chimney. If possible, you
should choose a location where the chimney will pass through the house
without cutting floor or roof joists (see fireplace dimensions on
Page 10).
Usually, no additional floor support is needed for the fireplace. The ad-
equacy of the floor can be checked by first estimating the weight of the
fireplace system. Weights are given in the appendix. Next, measure the
area occupied by the fireplace. Note the floor construction and consult
your local building code to determine if additional support is needed.
The WCT6840WS fireplace may be installed directly on the floor or on a
raised base and a minimum of 80” measured from the base of the appli-
ance to the ceiling is required.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7