Figure 16
Rain Cap
Flashing
Collar
Flashing
Roof Support
Attic
Radiation
Shield
Non-Combustible
Flameproof
Facing
Figure 17
Figure 15
When installing the double outlet system, the hot air outlets can be
installed in the same room as the fireplace, or one or both of the outlets
can be installed in adjacent or upper rooms. Installing the ducts at dif-
ferent elevations will tend to exhaust more heat out of the higher outlet
(Figure 16).
Frame
Grill
Maintain at least 6-1/2”
(160 mm) clearance from
the outlet grill framing to
a combustible ceiling,
side wall or mantel.
Outlet Grill
Outlet Grill
WARNING: The outlet
grills should not be
installed facing up-
ward through a floor.
Danger of burns can
result if grills in floor
are stepped on.
6-1/2” (165mm)
Min. (to ceiling)
Firestop
10’
(3.1m)
Max.
13” x 13”
(330mm x 330mm)
10’ (3.1m)
Max.
68” Min.
(1727mm)
56” Min.
(1422mm)
Fireplace Blower
The fireplace comes equipped with a heat activated blower. It is located
in the bottom of the fireplace, towards the back. It uses 120 V and must
be connected to the main electrical circuit by a qualified electrician. For
connection, use the electrical box supplied with the unit located on the
bottom right corner of the fireplace.
If you wish to adjust the blower speed, the variable speed control (VRUW)
provided must be installed in line with the wiring. Again, use a qualified
electrician for installation.
If the blower requires servicing,
1- Remove the doors and decorative facade.
2- Remove the screw located below the blower motor that holds it to the
back of fireplace.
3- Pull the blower out of the unit through the square hole located in the
front bottom right corner.
HOT AIR DUCTING INSTALLATION
The WCT6840WS fireplace is approved for use with a Gravity Kit:
Gravity Kit
The gravity kit is designed for double hot air outlets and includes:
(See
Figure 15)
- 2 telescopic lengths 8” I.D.
- 2 90º elbows 8” I.D.
- 2 hot air outlet kits (grill and frames)
- 2 adaptors
See
Gravity Kit Accessories
on
Page 21
.
Only the blower available with the fireplace can be used with the gravity
kit. For safe installation, the gravity kit must meet the following require-
ments:
Minimum height*
68” (1,727 mm)
Maximum length
See
Figure 16
* The height of the louver must be measured from the base of the
WCT6840WS fireplace to the middle point of the louver.
WARNING: Both pipes of
the double hot air outlet
must be installed. Any oth-
er installation may cause
fire and void warranty.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.