WARNING

If the information in this 

manual is not followed 

exactly, a fire or explosion 

may result causing prop-

erty damage, personal 

injury or loss of life.

       

IMPORTANT

Before starting your firebox instal-

lation, read these installation 

instructions carefully to be sure you 

understand them completely and 

in entirety. Failure to follow these 

instructions could cause a heater 

malfunction resulting in serious 

injury and/or property damage.

       

IMPORTANT

The fireplace screens on the appli-

ance must be closed prior to operat-

ing the fireplace.

       

WARNING

These built-in vent-free fireboxes 

have only been tested and approved 

for use with ANSI Z21.11.2 Vent-

free gas logs.

       

WARNING

Any change to this Vent-Free room 

heater can be dangerous. Improper 

installation or use of this heater can 

cause serious injury or death from 

fire, burns, explosion or carbon 

monoxide poisoning.

       

WARNING

Do not attempt to burn solid wood 

fuels, other gas log sets or any 

other combustible materials in 

this vent-free firebox.

       

WARNING

Carbon Monoxide Poisoning: Early 

signs of carbon monoxide poisoning 

are similar to the flu with head-

aches, dizziness and/or nausea. If 

you have these signs, obtain fresh 

air immediately. Have the Vent-Free 

Gas Heater serviced as it may not 

be operating correctly.

       

WARNINGS

• Due to high temperatures, the 

firebox should be located out of 

traffic and away from furniture 

and draperies.

• Do not place clothing or other 

flammable material on or near 

the heater.

• Any safety screen or guard re-

moved for servicing the firebox 

must be replaced and/or closed 

prior to operating the heater.

• Installation and repair should 

be done by a qualified service 

person. The heater should be 

inspected before use and at 

least annually by a professional 

service person. More frequent 

cleaning may be required due 

to excessive lint from carpet-

ing, bedding material, etc. It is 

important that control compart-

ments, burners and circulating 

air passageways of the heater 

be kept clean.

•  Allow the heater to cool before 

servicing. Always shut off any 

electricity or gas to the heater 

while performing service work.

• Do not install the firebox in a 

sleeping room or bathroom.

•  The appliance and its individual 

shut-off valve must be discon-

nected from the gas supply piping 

system while performing any 

tests of the gas supply piping 

system at test pressures equal 

to or less than 1/2 psig.

       

WARNING

•  The heater must be isolated from 

the gas supply piping system by 

closing its individual manual 

shut-off valve during any pres-

sure testing of the gas supply 

piping system at test pressures 

equal to or less than 1/2 psig.

•  Keep heater area clear and free 

from combustible materials, 

gasoline and other flammable 

vapors and liquids.

• Do not use this heater if any 

part has been under water. Im-

mediately call a qualified service 

technician to inspect the heater 

and to replace any part of the con-

trol system and any gas control 

which has been under water.

•  Ensure that the heater is clean 

when operating. Excessive dust 

accumulation on the burner and 

logs will increase the amount of 

carbon monoxide formation and 

could lead to carbon monoxide 

poisoning and death.

       

WARNING

Do not install in the vicinity where 

gasoline or other flammable liq-

uids may be stored. The Vent-Free 

firebox must be kept clear and free 

from these combustible materials.

       

WARNING

Maintain minimum clearances.

       

WARNING

Do not allow fans to blow directly 

into the fireplace. Avoid any drafts 

that alter burner flame patterns.

Summary of Contents for VRT3536WH

Page 1: ...IONS REQUIREDFORTHEINSTALLATIONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST B...

Page 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Page 3: ...BEGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approve...

Page 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the...

Page 5: ...Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WA...

Page 6: ...side of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instr...

Page 7: ...area above Models VRT3536 VRT3542 Series WITH Hood Installed Hood is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and...

Page 8: ...is unique however and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is t...

Page 9: ...ramed depth from a framed wall must always be measured from a finished surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall su...

Page 10: ...200 lbs 22 Cu Ft F0300 VRT3542WS 230 lbs 26 Cu Ft F0301 VRT3542WH 230 lbs 26 Cu Ft Dimensions Inches millimeters Model No A B C D E F G H J K L M N P Q VRT3536WS VRT3536WH 36 914 28 711 41 3 4 1061 41...

Page 11: ...vel and secure Step 3 Reinstall screen and rod assemblies see Figure 11 Framing Dimensions Opening VRT3536 Series VRT3542 Series A 42 1 4 1073 48 1 4 1226 B 44 1 4 1124 44 1 4 1124 C 23 5 8 600 29 5 8...

Page 12: ...ired Blower Tab Intact Plug blower into this receptacle Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with...

Page 13: ...rdtotakeupslack seeFigure20 Step 4 Locate the tabs shown in Figure 21 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the...

Page 14: ...22 VRT3542WS Shown Loose knot in power cord to take up slack Firebox floor Model VRT3542WS Shown Model VRT3542WS Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in pla...

Page 15: ...Raised Hearth Extension Non Combustible Wall see Figures 4 and 5 Page 7 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Vol...

Page 16: ...wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I N T The variable speed...

Page 17: ...y An exploded view of the firebox with numbered parts and a replacement parts list can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shippe...

Page 18: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Page 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Reviews: