NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

16

Outside Air Gate & Duct Kit

Cat. No.

Model No.

Description

H3991

OAK-UVFRC

Outside Air Gate & Duct Kit

Outside Air Gate & Duct Kit

These kits have an air gate assembly, 4" diameter 

duct and a termination hood.  The air gate allows 

adjustment of the amount of outside air delivered 

to the fire for combustion. Only one  kit, located 

on the right side of the fireplace, is required. 

(ref. Form  #750206M)

Blower Kit

The FBK-100 blower provides for a constant velocity forced air circulation feature for your ap-

pliance.  The FBK-200 assembly with variable speed wall switch provides a forced air circulation 

feature for your appliance.

Black Hood 

Cat. #

Model

Models Where Used

H1989

FC36

VRT3536 Series

H1990

FC42

VRT3542 Series

* Forced Air Blower Kits

Cat. 

No.

Model No.

Description

80L84

FBK-100

Blower, Standard

(single speed)

80L85

FBK-200

Blower, Variable Speed 

(w/wall-mounted switch)

Touch-Up Paint Kit

Repair of minor scratches and 

discoloration of the appliance 

black painted surfaces may be 

accomplished with the touch-up 

paint kit.

PA I N T

The variable speed control 

rheostat is included with 

FBK-200 models only

An ON/OFF wall switch can be used 

with the FBK-100 models (field 

supplied or order P/N 85L87 Wall 

Switch Kit, shown below)

ON/OFF Wall Switch Kit

The ON/OFF wall switch kit 

may be used to control the 

blower operation, if FBK-

100 blower kit is installed. 

Install the ON/OFF wall 

switch in a convenient 

location near the fireplace.

White Wall Switch Kit

Cat. No.

Model No.

Description

85L87

FWSK

ON/OFF Wall Switch Kit

  *  The installation of these kits also require a Junction Box / Receptacle 

Kit, not included.  See ordering information on this page.

(ref. Form  #750195M)

APPROVED ACCESSORIES AND 

COMPONENTS

For more information on available log sets for this and other Superior

®

 products, visit SuperiorFireplaces.us.com.

Touch-Up Paint Kit

Cat. No. Model No.

Description

F1882

SCTPSAB Black touch-up paint, powder 

coat (for firebox face and hood)

Summary of Contents for VRT3536WH

Page 1: ...IONS REQUIREDFORTHEINSTALLATIONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST B...

Page 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Page 3: ...BEGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approve...

Page 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the...

Page 5: ...Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WA...

Page 6: ...side of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instr...

Page 7: ...area above Models VRT3536 VRT3542 Series WITH Hood Installed Hood is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and...

Page 8: ...is unique however and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is t...

Page 9: ...ramed depth from a framed wall must always be measured from a finished surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall su...

Page 10: ...200 lbs 22 Cu Ft F0300 VRT3542WS 230 lbs 26 Cu Ft F0301 VRT3542WH 230 lbs 26 Cu Ft Dimensions Inches millimeters Model No A B C D E F G H J K L M N P Q VRT3536WS VRT3536WH 36 914 28 711 41 3 4 1061 41...

Page 11: ...vel and secure Step 3 Reinstall screen and rod assemblies see Figure 11 Framing Dimensions Opening VRT3536 Series VRT3542 Series A 42 1 4 1073 48 1 4 1226 B 44 1 4 1124 44 1 4 1124 C 23 5 8 600 29 5 8...

Page 12: ...ired Blower Tab Intact Plug blower into this receptacle Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with...

Page 13: ...rdtotakeupslack seeFigure20 Step 4 Locate the tabs shown in Figure 21 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the...

Page 14: ...22 VRT3542WS Shown Loose knot in power cord to take up slack Firebox floor Model VRT3542WS Shown Model VRT3542WS Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in pla...

Page 15: ...Raised Hearth Extension Non Combustible Wall see Figures 4 and 5 Page 7 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Vol...

Page 16: ...wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I N T The variable speed...

Page 17: ...y An exploded view of the firebox with numbered parts and a replacement parts list can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shippe...

Page 18: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Page 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Reviews: