background image

SuperiorFireplaces.us.com

126861-01P

30

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our 

web site at SuperiorFireplaces.us.com.

REPLACEMENT PARTS

See 

Pages 27 to 29

 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.

ACCESSORIES

Purchase these appliance accessories from your local dealer. If they can not supply these accessories, contact IHP at 

SuperiorFireplaces.us.com

 

for referral information. You can also write to the address listed on the back Page of this manual.

Only kits supplied by IHP shall be used in the installation of this appliance. Use of non-approved accessory/part kit(s) can result in 

poor performance and safety hazards.

CAT NO.

MODEL

DESCRIPTION

KIT

LINEAR DECORATIVE SURROUND KITS

Not Shown

F4216

DS-BLK-43

Decorative Surround for 43" Linear Fireplace - Black

F4217

DS-AS-43

Decorative Surround for 43" Linear Fireplace - Aged 

Silver

F4218

DS-AC-43

Decorative Surround for 43" Linear Fireplace - Aged 

Copper

LINEAR SEE-THRU CONVERSION KITS

Not Shown

F1030

LVSTI

Linear VF See-Thru Conversion Kit

F1031

LV43DS

43" Linear VF Draft Shield Kit

NOTE:

 Barrier kit cat. no. F2882 is required when installing 

this kit.

LINEAR BARRIER KIT

Not Shown

F2882

LVI43B

Linear 43 ID Barrier

NOTE:

 this kit is required when draft shield kit cat. no. F1031 

is installed

GLASS MEDIA

Blue

Amber

Green

F1097

GP43A

6.0 lb. Bag Smooth Glass Pebbles - Amber

F1098

GP43B

6.0 lb. Bag Smooth Glass Pebbles - Blue

F1099

GP43G

6.0 lb. Bag Smooth Glass Pebbles - Green

F1101

GP43C

6.0 lb. Bag Clear Glass Pebbles

If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1769 East Lawrence Street

Russellville, AL 35654

Visit us at SuperiorFireplaces.us.com

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  fireplace will not produce specified heat
•  propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local 

gas supplier.

Summary of Contents for VRL4543

Page 1: ...installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 7 of this manual WARNING If the information in this manua...

Page 2: ...trying to assemble operate or ser vicethisheater Improperuseofthisheatercancause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Aftermarket Completion...

Page 3: ...bustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Fireplaces become very hot when running firepla...

Page 4: ...off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This...

Page 5: ...a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shut off must be a...

Page 6: ...te of a structure is known the Known Air Infiltration Rate Method may be used Follow The National Fuel Gas Code ANSI Z223 1 NFPA 54 to use this method to determine if the space is confined or unconfin...

Page 7: ...ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fireplace if lower Btu Hr siz...

Page 8: ...ealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rating plate Field conv...

Page 9: ...16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf Noncombustible mat...

Page 10: ...7 1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 VRL4543 Series Dimensions Electrical Outlet Gas Line Access Gas Line Access...

Page 11: ...e LP gas equipment shutoff valve test gauge connection sediment trap optional tee joint pipe wrench approved flexible gas line with gas connector if allowed by local codes not provided An equipment sh...

Page 12: ...diment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is...

Page 13: ...he gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its eq...

Page 14: ...a guide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing...

Page 15: ...ont of the fireplace unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner bracket...

Page 16: ...ner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to program the remote transmi...

Page 17: ...supplied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct...

Page 18: ...tory default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg...

Page 19: ...Flame A setting number will flash in the FLAME Zone REMOTE CONTROL OPERATION Continued LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Availa...

Page 20: ...rt of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS This appliance requires 120V electricity for normal operation Control module should be plugged into electr...

Page 21: ...ave heater inspected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using com...

Page 22: ...the fireplace running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create so...

Page 23: ...ot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY PACK WIRING DIAGRAM Black Blk White SIZE AA SIZE AA SIZE AA SIZE AA Blk Brown Yello...

Page 24: ...ontact local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance Page 21 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Cl...

Page 25: ...cting while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance Page 21 1 Refer to Air for Com...

Page 26: ...LP only 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas co...

Page 27: ...4 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12 Cat No Description F1186 VRL4543ZEN F1187 VRL4543ZEP WARNING Failure to position the parts in accordance with these diagrams or failure to use only p...

Page 28: ...tery Backup 1 20 J6205 Battery Backup 1 21 J6833 Connector 3 8 Tube x 3 8 MPT 1 22 J8033 Valve NG 1 J8040 Valve LP 1 23 J7939 Control Module Skytech AF4000MOD 1 24 J6868 Switch Rocker ON OFF Remote 1...

Page 29: ...S VRL4543ZEN VRL4543ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heat...

Page 30: ...essory part kit s can result in poor performance and safety hazards CAT NO MODEL DESCRIPTION KIT LINEAR DECORATIVE SURROUND KITS Not Shown F4216 DS BLK 43 Decorative Surround for 43 Linear Fireplace B...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126861 01 Rev P 01 2020 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us...

Reviews: