SuperiorFireplaces.us.com
126861-01P
4
PRODUCT IDENTIFICATION
Figure 1 - Vent Free VRL4543 Fireplace
2. Do not place propane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors (propane/LP only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your
building
• leave the building immediately
• immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4. This fireplace shall not be installed in a bedroom or bathroom.
5. Do not use this fireplace as a wood-burning fireplace. Use only
the logs provided with the fireplace.
6. Do not add extra logs or ornaments such as pine cones, vermicu-
lite, or rock wool. Using these added items can cause sooting.
Do not add lava rock around base. Rock and debris could fall into
the control area of fireplace.
7. This fireplace is designed to be smokeless. If logs ever appear
to smoke, turn off fireplace and call a qualified service person.
NOTE
: During initial operation, slight smoking could occur due
to log curing and fireplace burning manufacturing residues.
8. To prevent the creation of soot, follow the instructions in Cleaning
and Maintenance,
Page 21
.
9. Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these prod-
ucts may create a white powder residue within burner box or on
adjacent walls or furniture.
10. This fireplace needs fresh air ventilation to run properly. This
fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the fireplace if not enough fresh
air is available. See Air for Combustion and Ventilation,
Page 6
.
If fireplace keeps shutting off, see Troubleshooting,
Page 24
.
11. Do not run fireplace
• where flammable liquids or vapors are used or stored.
• under dusty conditions.
12. Do not use this fireplace to cook food or burn paper or other
objects.
13. Do not use fireplace if any part has been under water. Immediately
call a qualified service technician to inspect the room fireplace
and to replace any part of the control system and any gas control
which has been under water.
14. Turn off and unplug fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
15. Operating fireplace above elevations of 4,500 feet could cause
pilot outage.
16. To prevent performance problems, do not use propane/LP fuel
tank of less than 100 lbs. capacity (propane/LP only).
17. Provide adequate clearances around air openings.
18. The screen or any other part removed for servicing must be
replaced prior to operating this heater.
1. WARNING: This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convert-
ible for use with other gases.
SAFETY
Continued
Pebble Pan
Access Door
Top Spacers
Left Side
Right Side
Front
Nailing
Flange