VENTING INSTALLATION  

Continued

There are three vent kits available which have been specially de-

signed for common installations in manufactured (mobile) homes: 

MW8K (8' vent kit), MW9K (9' vent kit) and MW8K-HT (8' HT vent 

kit). Contents of these kits are listed under Accessories on 

page 19

IMPORTANT:

 If height of chimney assembly exceeds requirements 

for transportation of home, chimney installation may be completed 

after home is sited. 

NOTE

: Termination must always be installed after the home is sited.

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

Each double wall chimney section consists of a galvanized outer pipe, 

a stainless steel inner flue pipe and a wire spacer. Pipe sections must 

be assembled independently as chimney is installed. When connecting 

chimney directly to fireplace, inner flue pipe section must be installed 

first with lanced side up. Outer pipe section can then be installed over 

flue pipe section with hemmed end up. Press down on each pipe section 

until lances securely engage hem on fireplace starter. Wire will assure 

proper spacing between inner and outer pipe sections.

Note:

 For Canada, use chimney parts designated HT.

     WARNING

The opening in the collar around the chimney at the top 

of the fireplace must not be obstructed. Never use blown 

insulation to fill the chimney enclosure.

Continue to assemble chimney sections as outlined above, making 

sure that both inner and outer pipe sections are locked together. When 

installing double wall snap-lock chimney together, it is important to 

assure that the joint between chimney sections is locked. Check by 

pulling chimney upward after locking. Chimney will not come apart 

if properly locked. It is not necessary to add screws to keep chimney 

together (exception, see 

Figure 27, page 13

)

ADJUSTABLE FIRESTOP THIMBLE

This adjustable thimble adjusts to the most commonly used ceiling 

pitches automatically. Refer to the following procedure for installing 

the adjustable thimble:
The adjustable thimble may be installed around the chimney com-

ponents at assembly or the chimney components may be inserted 

though the installed thimble.
Install the thimble from below a finished roof and ceiling assembly. 

Push the thimble assembly (tube section first) up into an already 

prepared opening and secure open end of the thimble base to the 

finished underside of the roof and ceiling assembly (Figure 13).

Note:

 The two screws on which the thimble base pivots may be 

removed and reinstalled into any of the series of placement holes 

provided for the adjustment of the adjustable thimble's point of 

rotation (Figure 10). Adjust the pivot screens to locate the open end 

of the tube section as required for the roof line. Additional screws 

may be placed at the high and low points of the thimble base in the 

tabs provided.
Place the thimble base against the finished roof and ceiling assembly 

and secure it to the framing with screws or nails. The thimble is self-

adjusting around inserted chimney components. Thimble extensions 

are available and may be installed into the adjustable thimble's tube 

The chimney system approved for this fireplace consists of 12", 

18", 24", 36" and 48" snap-lock, double-wall pipe segments, 

planned for maximum adaptability to individual site requirements. 

Actual lengths gained after fitting overlaps must be taken into 

consideration (lineal gain) and are given in lineal gain chart (see 

Figure 8). Lineal gain is actual measurable length of a part after 

two or more parts are connected.

Figure 8 - Lineal Gain

Hemmed 

End

8" Stainless 

Inner Pipe

12 

3

/

8

" Galvanized 

Outer Pipe

LINEAL GAIN

CAT. NO. PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37 

1

/

2

"

F0895

F0881

12-8DM

12-8HT

Pipe Section

10 

5

/

8

"

F0896

F0882

18-8DM

18-8HT

Pipe Section

16 

5

/

8

"

F0897

F0883

24-8DM

24-8HT

Pipe Section

23 

5

/

8

"

F0898

F0884

36-8DM

36-8HT

Pipe Section

34 

5

/

8

"

F0899

F0885

48-8DM

48-8HT

Pipe Section

46 

5

/

8

"

F0916

RT-8DM

Round Termination

7

/

8

"*

RTL-8DM

Round Termination

3

/

4

"*

F0918

RLT-8DM

Round Termination

1

/

2

"*

F0917

RTT-8DM

Round Termination with 

Slip Section

7

/

8

" to 

23 

1

/

8

"*

RTTL-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

2

"*

F0919

RLTT-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

4

"*

F0920

ET-8DM

Square Chase-Top

12"*

F0922

ETO-8DM

Square Chase-Top with 

Mesh

12"*

F0921

ETL-8DM

Square Chase-Top with 

Slip Section

7" to 15"*

F0923

ETLO-8DM

Square Chase-Top with 

Mesh & Slip Section

12" to  

25 

1

/

2

"*

* The lineal gain for the terminations is measured to the flue gas 

outlet height.

Summary of Contents for MHWB36CB

Page 1: ...ent free log heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determ...

Page 2: ...n sibility for the following actions a Modificationofthefireplace components doors airinletsystem and damper control b Use of any component part not manufactured or approved by IHP in combination with...

Page 3: ...efluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service technician Some people are more affected by carbon monoxide than...

Page 4: ...S THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT LEFT SIDE 13 7 8 353 mm 9 1 8 232 mm 3 4 1...

Page 5: ...stem is 50 feet This measurement includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 27 page 13 FRAMING 1 Frame opening for fireplace using di...

Page 6: ...o Combustible Material 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 6 153 mm Min 9 229 mm Min 12 305 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of Combustible Materials Uppe...

Page 7: ...ach outside air vent termination 6 Construct an 8 x 8 inside framing or opening on exterior wall 7 Install outside air vent termination in a location that would not eventually be obstructed by bushes...

Page 8: ...Install the thimble from below a finished roof and ceiling assembly Push the thimble assembly tube section first up into an already prepared opening and secure open end of the thimble base to the fini...

Page 9: ...boveceilinglevel firestopspacermustbeinstalled on the bottom side of the ceiling If an attic is above ceiling level firestop thimble must be installed on the bottom side of ceiling joist Figure 14 Not...

Page 10: ...64 1 2 134 3 8 1 2 1 67 1 4 139 5 8 4 VENTING INSTALLATION Continued Figure 14 Installing Thimble Outer Pipe Thimble Cathedral Ceiling 14 Min Outer Pipe Of Chimney PENETRATING ROOF To maintain a 1 cle...

Page 11: ...etrate inner stainless FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance be...

Page 12: ...3 Places Secure with Screws RLT 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 23 Termination Overlap Shingles Top and Sides Flue Pipe of RLT 8DM Inside Inner...

Page 13: ...92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 25 10 Foot Rule CHIMNEY SUPPORT BRACKET KIT CSK 8DM If exposed portion of chimney is greater than five feet above roofline support wires are recom...

Page 14: ...g that the gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERAT...

Page 15: ...in this fireplace Always keep fire back from doors and never allow flames to contact glass OPTIONAL GAS LINE INSTALLATION Continued FINISHING FIREPLACE Combustible materials such as wallboard gypsum...

Page 16: ...yhole slot then pull down and forward to lock it in place see Figure 34 Vent damper must be locked in the full open position before operating fireplace Figure 33 Damper Handle Location Damper Handle W...

Page 17: ...fireplace ready You can also visit our web site at Superiorfireplaces US com CAT NO MODEL DESCRIPTION BI FOLD GLASS DOORS F0972 BDB36 36 Standard Black Finish Included F0973 BDB36B 36 Standard Brushed...

Page 18: ...600FS 8DM 1 1 Clearance Firestop Spacer ROOF FLASHING F0909 V6F 8DM Roof Flashing 0 to 6 12 Pitch 30 Base F0910 V12F 8DM Roof Flashing 6 12 to12 12 Pitch CHIMNEY SUPPORT BRACKET KIT Support Bracket Se...

Page 19: ...ce Hood ADJUSTABLE FIRESTOP THIMBLE Not shown F2696 LB 97008A Adjustable Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clea...

Page 20: ...Superiorfireplaces US com 900671 00_NC 20 PARTS WOOD BURNING FIREPLACE MODEL MHWB36CB 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 30 13 29 8 26 6 19 21...

Page 21: ...Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20 J6918 Top Standoff 4 21 J6893 Chimney Starter Collar 1 22 Door...

Page 22: ...4 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Suppor...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...aler name P900671 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produc...

Reviews: