IMPORTANT NOTICE

A manufactured shroud which 

has been approved by a na-

tional testing agency for use 

with this fireplace may be used 

if installed in accordance with 

the instructions by its manu-

facturer. A locally fabricated 

shroud may be used with IHP 

Shroud Leg Spacer Kit (SLK) 

in accordance with instructions 

provided with the shroud.

Canadian code CAN/ULC-S610-M87 and other pertinent 

codes require stainless steel chimney for the installation 

of this fireplace. A Cold Air Climate Kit is also required 

in Canada and is recommended for cooler regions in the 

United States. Below, find a list of approved stainless 

steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model No. 8" Hi-Temp  

Wood burning Chimney

F0881

12-8HT

12" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0886

30E-8HT

30 Degree Hi-Temp Offset 

and Return

F0887

12S-8HT

Hi-Temp Chimney Support 

(For Use With Chimney 

Heights In Excess of 30')

F0888

RT-8HT

Hi-Temp Round Top with 

Mesh Screen

F0889

RTT-8HT

Hi-Temp Round Top with 

Mesh Screen and Slip Sec-

tion

F0890

RLT-8HT

Hi-Temp Round Top with 

Louvered Screen

F0891

RLTT-8HT

Hi-Temp Round Top with 

Louvered Screen and Slip 

Section

F0892

ET-8HT

Hi-Temp Pyramid Top with 

Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top 

with Slip Section (use with all 

8" systems)

F0894

AP-8HT

Hi-Temp Anchor Plate/Col

-

lar Assembly (for masonry 

fireplaces)

F0929

CAK-8

Cold Air Collar Kit - 8" 

Chimney

*When ordered alone, this part cannot ship via parcel 

delivery services.

NOTICE: The firebox canopy (hood) 

must not be modified or replaced with 

a canopy that may be provided with 

the unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEG-

RITY OF THE MANUFACTURED HOME 

FLOOR, WALL, AND CEILING/ROOF 
MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL 

IN SLEEPING ROOM OF MOBILE 

HOMES.

ACCESSORIES 

Continued

Summary of Contents for MHWB36CB

Page 1: ...ent free log heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determ...

Page 2: ...n sibility for the following actions a Modificationofthefireplace components doors airinletsystem and damper control b Use of any component part not manufactured or approved by IHP in combination with...

Page 3: ...efluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service technician Some people are more affected by carbon monoxide than...

Page 4: ...S THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT LEFT SIDE 13 7 8 353 mm 9 1 8 232 mm 3 4 1...

Page 5: ...stem is 50 feet This measurement includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 27 page 13 FRAMING 1 Frame opening for fireplace using di...

Page 6: ...o Combustible Material 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 6 153 mm Min 9 229 mm Min 12 305 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of Combustible Materials Uppe...

Page 7: ...ach outside air vent termination 6 Construct an 8 x 8 inside framing or opening on exterior wall 7 Install outside air vent termination in a location that would not eventually be obstructed by bushes...

Page 8: ...Install the thimble from below a finished roof and ceiling assembly Push the thimble assembly tube section first up into an already prepared opening and secure open end of the thimble base to the fini...

Page 9: ...boveceilinglevel firestopspacermustbeinstalled on the bottom side of the ceiling If an attic is above ceiling level firestop thimble must be installed on the bottom side of ceiling joist Figure 14 Not...

Page 10: ...64 1 2 134 3 8 1 2 1 67 1 4 139 5 8 4 VENTING INSTALLATION Continued Figure 14 Installing Thimble Outer Pipe Thimble Cathedral Ceiling 14 Min Outer Pipe Of Chimney PENETRATING ROOF To maintain a 1 cle...

Page 11: ...etrate inner stainless FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance be...

Page 12: ...3 Places Secure with Screws RLT 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 23 Termination Overlap Shingles Top and Sides Flue Pipe of RLT 8DM Inside Inner...

Page 13: ...92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 25 10 Foot Rule CHIMNEY SUPPORT BRACKET KIT CSK 8DM If exposed portion of chimney is greater than five feet above roofline support wires are recom...

Page 14: ...g that the gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERAT...

Page 15: ...in this fireplace Always keep fire back from doors and never allow flames to contact glass OPTIONAL GAS LINE INSTALLATION Continued FINISHING FIREPLACE Combustible materials such as wallboard gypsum...

Page 16: ...yhole slot then pull down and forward to lock it in place see Figure 34 Vent damper must be locked in the full open position before operating fireplace Figure 33 Damper Handle Location Damper Handle W...

Page 17: ...fireplace ready You can also visit our web site at Superiorfireplaces US com CAT NO MODEL DESCRIPTION BI FOLD GLASS DOORS F0972 BDB36 36 Standard Black Finish Included F0973 BDB36B 36 Standard Brushed...

Page 18: ...600FS 8DM 1 1 Clearance Firestop Spacer ROOF FLASHING F0909 V6F 8DM Roof Flashing 0 to 6 12 Pitch 30 Base F0910 V12F 8DM Roof Flashing 6 12 to12 12 Pitch CHIMNEY SUPPORT BRACKET KIT Support Bracket Se...

Page 19: ...ce Hood ADJUSTABLE FIRESTOP THIMBLE Not shown F2696 LB 97008A Adjustable Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clea...

Page 20: ...Superiorfireplaces US com 900671 00_NC 20 PARTS WOOD BURNING FIREPLACE MODEL MHWB36CB 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 30 13 29 8 26 6 19 21...

Page 21: ...Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20 J6918 Top Standoff 4 21 J6893 Chimney Starter Collar 1 22 Door...

Page 22: ...4 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Suppor...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...aler name P900671 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produc...

Reviews: