SuperiorFireplaces.us.com
900807-00_A
12
INSTALLATION
Continued
A
B
1/2" NPT Incoming
Black Iron Gas Line
Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side
7"
7"
Alternate Gas Supply
Through Sub-Floor
Figure 18 - Sediment Trap
Figure 17 - Routing Incoming Gas Line
3" Min.
(7.6 cm)
Side W
all
Of Appliance
Incoming 1/2" Gas
Line Permitted by
Local Codes
Sediment
Trap (Not
Supplied)
BRT 4036TEN-B, 4336TEN-B,
4536TEN-B, 4036TEP-B,
4336TEP-B, 4536TEP-B
BRT 4042TEN-B, 4342TEN-B,
4542TEN-B, 4042TEP-B,
4342TEP-B, 4542TEP-B
A
8
5
/
8
" (21.9 cm)
10
1
/
2
" (26.7 cm)
Figure 19 - Connecting Flexible Gas Line to Millivolt Valve
P
IL
O
T
ON
OFF
IN
OUT
Gas Shutoff
Valve
Flexible Gas Line
Do NOT Kink
1/2" NPT
Incoming
Gas Line
NOTE:
1) Wire Connections
Not Shown for Clarity
2) * 1/8" NPT Plugged
Tapping
Red Surface Indicates For
Propane/LP Use Only
Pilot
Adj
Inlet Pressure Tap
Outlet
Pressure Tap
Figure 20 - Place Vermiculite on Burner Pan per Instructions
Figure 21 - Ember Material on Surface of Pan Material (Vermiculite)
Vermiculite
(Pan Material)
Burner Pan
Grate
Ember
Material
Burner
Pan
Vermiculite (Pan Material)
Grate
EMBER AND PAN MATERIAL PLACEMENT
1. Open bag(s) of vermiculite and fill until it is even across burner
pan
(see Figure 20).
2. Smooth pan material just even with edges of burner pan.
3. Remove ember material from bag and flatten small amounts into
quarter size pieces and lay on top of surface of pan material
(see
Figure 21).
4. Place just enough ember material to cover burner pan material.
Leave a 1/2" space between pieces.
CAUTION: Compounds used on threaded joints of
gas piping shall be resistant to the action of Liquefied
Petroleum (LP or propane) and should be applied lightly
to ensure excess sealant does not enter the gas line.
WARNING: All gas piping and connections must be
tested for leaks after the installation is completed.
After ensuring that the gas valve is on, apply a com-
mercial leak detection solution to all connections and
joints. If bubbles appear, leaks can be detected and
corrected.
Do not use an open flame for leak testing and do not
operate any appliance if a leak is detected.
Complete your gas installation by connecting incoming gas line
with flexible gas line. Secure tightly with wrench but DO NOT OVER-
TIGHTEN.