COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS

These appliances are approved for installation in the US state of Mas-

sachusetts if the following additional requirements are met:
•  Install this appliance in accordance with Massachusetts Rules and 

Regulations 248 C.M.R. Sections 4.00 through 8.00.

•   Installation and repair must be done by a plumber or gas fitter 

licensed in the Commonwealth of Massachusetts.

•   The flexible gas line connector used shall not exceed 36 inches 

(92 centimeters) in length.

•   The individual manual shut-off must be a T-handle type valve.

INTRODUCTION

All 36" and 42" models listed within this manual are vented gas fireplaces 

that use an electronic control valve and electronic ignition system. A 6" 

B-Type venting system and a listed type vent cap are not supplied but are 

required for proper operation. See venting instructions on 

Pages 9 and 10

.

 

WARNING: This gas appliance must not be con-

nected to a chimney flue serving a separate solid-fuel 

burning appliance.

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instruc-

tions through completely.
This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) appliance and 

its approved components are safe when installed according to this 

installation manual and are operated as recommended by IHP. Unless 

you use IHP approved components tested for this appliance, YOU 

MAY CAUSE A FIRE HAZARD!
The IHP warranty will be voided by and IHP disclaims any responsibil-

ity for the following actions :
A)  Modification of the appliance or any of the components.
B)  Use of any component part not approved by IHP in combination 

with this appliance.

C)  Installation and/or operation in a manner other than instructed in 

this manual.

D)  Burning of anything other than the type of gas approved for use in 

this gas appliance.

UNPACKING

The following items are packed inside the firebox. Remove before 

positioning firebox into framing.
•  Transition Collar - For vent connection
•  Ceramic Log Pack - Shrink-wrapped on cardboard
•  Three (3) plastic bags containing volcanic stone rock, pan and 

ember materials

•  Rear Log - Remove the two plastic quick ties from around the 

burner and grate

•  Grate Stand - Lift off of burner pan
Check all items for any shipping damage. If damaged, promptly inform 

dealer or distributor where you purchased the product.
Safely retain these items for later installation.

CODES AND STANDARDS

These fireplaces comply with National Safety Standards and are 

tested and listed by PFS Corporation (Report No. F09-143) to ANSI 

Z21.50 (in Canada, CSA-2.22) in both USA and Canada, as vented 

gas fireplaces. The installation must conform to local codes or, in the 

absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA 54—latest edition (In Canada, the current CAN/CGA-B149.1 

installation code). The fireplace, when installed, must be electrically 

grounded and wired in accordance with local codes or, in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70—lat-

est edition, or the Canadian Electrical Code, CSA C22.1—latest edition.

SAFETY  

Continued

20. Provide adequate clearances around air openings.

21. Children and adults should be alerted to the hazards of high sur-

face temperature and should stay away to avoid burns or clothing 

ignition.

22. Clothing or other flammable material should not be placed on or 

near the appliance.

23. The draft hood be installed so as to be in the same atmospheric 

pressure zone as the combustion air inlet to the appliance and 

shall be located so that the relief opening is accessible for checking 

vent operation.

Summary of Contents for BRT4036TEN-B

Page 1: ...ppelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installatione...

Page 2: ...d its installation complies with State and Local Codes and in the absence of these codes complies with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code C...

Page 3: ...depth of the fireplace 17 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 18 Do not operate fire...

Page 4: ...nner other than instructed in this manual D Burning of anything other than the type of gas approved for use in this gas appliance UNPACKING The following items are packed inside the firebox Remove bef...

Page 5: ...INSTALLATION FLUSH INSTALLATION WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need a building pe...

Page 6: ...000 Btu Hr Manifold Pressure 10 WC 2 50 kPa 10 WC 2 50 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Mode...

Page 7: ...0 0 mm min B Vent Surfaces 1 26 mm min Ceiling to Opening 42 1067 mm min Floor 0 0 mm min Perpendicular Wall See Figure 6 Front Service Clearances 3 0 9 M BRT 4036TEN B 4336TEN B 4536TEN B 4036TEP B...

Page 8: ...5 16 above bottom of appliance The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance see Figure 17 Page 12 4 Repack insulation around...

Page 9: ...rminated into an attic space or into a chimney flue servicing a solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adap...

Page 10: ...Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2...

Page 11: ...eady to use 5 Replace front refractory access panel Figure 16 Manual Shutoff Valve Installation Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Figure 15 Installing Battery...

Page 12: ...aterial Burner Pan Vermiculite Pan Material Grate EMBER AND PAN MATERIAL PLACEMENT 1 Open bag s of vermiculite and fill until it is even across burner pan see Figure 20 2 Smooth pan material just even...

Page 13: ...26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26 As an option to enhance t...

Page 14: ...p right of log 1 see Figure 29 Rest lower end of log 6 on top of log 2B see Figure 30 As an option to enhance the look of the hearth you may place volcanic stone provided around front and sides of bur...

Page 15: ...31 Pull handle to open or push to close APPLIANCE ENCLOSURE Before finishing enclosure around appliance inspect all joints around outer surround Any gaps between nailing flanges and framing should be...

Page 16: ...s operating Do not attempt to adjust or clean the glass doors until the appliance has fully cooled CAUTION Always operate the appliance with the doors either fully opened or fully closed Operating the...

Page 17: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE Duringinitialoperationofnewfireplace burn ing logs will give off a paper burning smell Orange flame will als...

Page 18: ...ing may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circulating air system be kept clean WARNING Turnoffga...

Page 19: ...is equipped with a manually reset blocked flue safety limit switch Refer to Figure 42 for its location If during appliance operation the flame goes out independently of the burner on off wall switch...

Page 20: ...sit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Page 21: ...an any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replace control valve refer to Re placement Parts Page 20 7 Check th...

Page 22: ...op of Page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Gas Line Hook Up Page 11 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air hole...

Page 23: ...36TEP B White Herringbone F3200 BRT4536TEN B White Herringbone F3213 BRT4342TEP B White Stacked F3212 BRT4342TEN B White Stacked F3209 BRT4336TEP B White Stacked F3208 BRT4336TEN B White Stacked F3221...

Page 24: ...E ASSEMBLY 1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 1 31 J7320...

Page 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Page 26: ...45 LOG 11 TOP 1 KEY NO CATALOG NO DESCRIPTION QTY J4097 LOG SET 1 J7242 LOG REAR 27 1 2A J4245 LOG 11 TOP 1 2B J4262 LOG FIRE PIT 15 75 RND Y 1 3 J4244 LOG 13 5 Y TOP SPLIT 1 4 J4261 LOG 15 75 FIREPIT...

Page 27: ...36 Fixed Glass Door Brushed Brass finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 4...

Page 28: ...rim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1124 PCBE 36 36 Electronic Ignition NG to LP F112...

Page 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...eplace uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...

Reviews: