Figure 31 - Air Kit Handle Location

Air Kit 

Handle

Screen 

Pocket

Figure 32 - Sealing Between Appliance and Framing

Side 

Framing

Side 

Framing

Caulk Here

Pack Insulation

Figure 33 - Installing Optional Glass Door

Spring Clip

Insert Pin Into Spring Clip

Insert Bottom Pivot Pin Into 

Pivot Plate and Swing Door 

Into Vertical Position

Pivot Plate

Slide Top 

Pin Into 

Door Track

INSTALLATION  

Continued

6.  Repeat process for opposite door assembly.
7.  To adjust doors, slide them partially open. Using a screwdriver, 

loosen hold-down screws in the spring clip 

(see Figure 34, Page 

16)

 and pivot plate.

8.  Close both doors until evenly joined at the middle and note gap at 

outer edges of face.

9.  Reopen one door at a time and retighten upper and lower hold-

down screws.

 CAUTION: Air inlet ducts are not to terminate in 

attic space.

 CAUTION: Use only glass doors certified for use 

with this appliance.

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)
The outside air kit may be installed on the left side of fireplace only. 

The vent can be installed through any outside wall a minimum of three 

feet below fireplace termination cap. The handle to operate damper 

door for outside air inlet will be located inside left “screen pocket” of 

firebox 

(see Figure 31)

. Pull handle to open or push to close.

APPLIANCE ENCLOSURE
Before finishing enclosure around appliance, inspect all joints around 

outer surround. Any gaps between nailing flanges and framing should 

be sealed with noncombustible insulation or caulking.
If appliance is mounted on a raised platform, it must be a continuous 

surface and not on blocks without a solid surface. This will prevent 

entry of cold air by means of conduction through the total bottom of 

appliance 

(see Figure 32)

.

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

NOTE:

 Glass door may be heavy for some individuals. If this is the 

case, please request help if needed.
The BRT4036, BRT4336, BRT4536, BRT4042, BRT4342 and BRT4542 

B-vent fireplaces are approved for use with optional bi-fold glass 

doors 

(see Accessories, Page 27).

 Glass panels may be ordered and 

installed anytime after fireplace installation is complete.
Follow these steps to install left and right panels:
1.  With handle at the bottom, completely fold panel on its hinges.

2.  With handle facing center of firebox opening, insert lower pivot pin on 

glass door panel into hole in pivot plate on bottom edge of fireplace 

opening 

(see Figure 33).

3.  Keeping folded door tilted, slide upper two pins into guide track 

found under upper facial edge of firebox opening. 

4.  Tilt glass assembly fully vertical until outer pivot pin snaps into 

mounting hole in upper spring clip 

(see Figure 33)

.

5.  Once top and bottom pins are secured, unfold door into the closed 

position.

Summary of Contents for BRT4036TEN-B

Page 1: ...ppelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installatione...

Page 2: ...d its installation complies with State and Local Codes and in the absence of these codes complies with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code C...

Page 3: ...depth of the fireplace 17 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 18 Do not operate fire...

Page 4: ...nner other than instructed in this manual D Burning of anything other than the type of gas approved for use in this gas appliance UNPACKING The following items are packed inside the firebox Remove bef...

Page 5: ...INSTALLATION FLUSH INSTALLATION WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need a building pe...

Page 6: ...000 Btu Hr Manifold Pressure 10 WC 2 50 kPa 10 WC 2 50 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Mode...

Page 7: ...0 0 mm min B Vent Surfaces 1 26 mm min Ceiling to Opening 42 1067 mm min Floor 0 0 mm min Perpendicular Wall See Figure 6 Front Service Clearances 3 0 9 M BRT 4036TEN B 4336TEN B 4536TEN B 4036TEP B...

Page 8: ...5 16 above bottom of appliance The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance see Figure 17 Page 12 4 Repack insulation around...

Page 9: ...rminated into an attic space or into a chimney flue servicing a solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adap...

Page 10: ...Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2...

Page 11: ...eady to use 5 Replace front refractory access panel Figure 16 Manual Shutoff Valve Installation Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Figure 15 Installing Battery...

Page 12: ...aterial Burner Pan Vermiculite Pan Material Grate EMBER AND PAN MATERIAL PLACEMENT 1 Open bag s of vermiculite and fill until it is even across burner pan see Figure 20 2 Smooth pan material just even...

Page 13: ...26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26 As an option to enhance t...

Page 14: ...p right of log 1 see Figure 29 Rest lower end of log 6 on top of log 2B see Figure 30 As an option to enhance the look of the hearth you may place volcanic stone provided around front and sides of bur...

Page 15: ...31 Pull handle to open or push to close APPLIANCE ENCLOSURE Before finishing enclosure around appliance inspect all joints around outer surround Any gaps between nailing flanges and framing should be...

Page 16: ...s operating Do not attempt to adjust or clean the glass doors until the appliance has fully cooled CAUTION Always operate the appliance with the doors either fully opened or fully closed Operating the...

Page 17: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE Duringinitialoperationofnewfireplace burn ing logs will give off a paper burning smell Orange flame will als...

Page 18: ...ing may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circulating air system be kept clean WARNING Turnoffga...

Page 19: ...is equipped with a manually reset blocked flue safety limit switch Refer to Figure 42 for its location If during appliance operation the flame goes out independently of the burner on off wall switch...

Page 20: ...sit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Page 21: ...an any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replace control valve refer to Re placement Parts Page 20 7 Check th...

Page 22: ...op of Page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Gas Line Hook Up Page 11 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air hole...

Page 23: ...36TEP B White Herringbone F3200 BRT4536TEN B White Herringbone F3213 BRT4342TEP B White Stacked F3212 BRT4342TEN B White Stacked F3209 BRT4336TEP B White Stacked F3208 BRT4336TEN B White Stacked F3221...

Page 24: ...E ASSEMBLY 1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 1 31 J7320...

Page 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Page 26: ...45 LOG 11 TOP 1 KEY NO CATALOG NO DESCRIPTION QTY J4097 LOG SET 1 J7242 LOG REAR 27 1 2A J4245 LOG 11 TOP 1 2B J4262 LOG FIRE PIT 15 75 RND Y 1 3 J4244 LOG 13 5 Y TOP SPLIT 1 4 J4261 LOG 15 75 FIREPIT...

Page 27: ...36 Fixed Glass Door Brushed Brass finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 4...

Page 28: ...rim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1124 PCBE 36 36 Electronic Ignition NG to LP F112...

Page 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...eplace uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...

Reviews: