Superabrasive
Owner’s manual original language – Lavina
®
LP36GE
1/2022
22
7.4 CONTROL BOARD
1 CO Shut-off Module – KEEP IT DRY ALL TIMES!
Normal Operating Temperature: -40°F (-40°C) to 158°F (70°C)
Activation Levels (Relay Normally Open)
35 ppm TWA for 1 hour = Yellow LED flashing
>200 ppm for 5 minutes = Red LED flashing and relay activation
>400 ppm for 35 seconds = Red & Yellow LED flashing and relay activation
If the 35 ppm level is triggered it will flash the yellow LED. If either of the higher levels are reached the pattern will
switch over.
All activation levels will clear when the average ppm < 35 ppm
Low battery or Sensor self-diagnostics will trigger an EOL signal.
EOL Signal = Yellow LED flashing and buzzer chirp every 60 seconds.
2 Pump ON/OFF switches
3 Emergency button used to stop the motor in case of emergency
4 Lights ON/OFF switch
5 Electronics Module of digital fuel control system. Indicates the revolutions per minute of the engine, the worked
hours, the hour meters and reminders for checks.
6
QR code. When you scan it with your phone, it will redirect your browser to Lavina manuals page.
7 Cup holder
8 USB charger
9 Start/Stop Engine switch. Turn key fully to the right (make contact) to ignite the engine. Fully to the left will arrest
the engine.
Figure 7.4