4.3. Maintenance

NO INTERNAL MAINTENANCE 

IS REQUIRED OR SHOULD BE 

PERFORMED.  

OPENING THE CASE WILL 

VOID THE WARRANTY.  

5. USEFUL INFORMATION
5.1. Accessories and spare parts

The accessories used with the 

O2 concentrator

 

must:

 •

  be oxygen compatible.

 •

  be biocompatible.

            

The  connectors,  tubes  must  be  designed  for 

oxygen usage.

5.2. Materials in direct or indirect contact 

with the product output  

 

 Concentrator casing ................................ABS

 Power Cord  ........................................... PVC

 Cabinet Air Filter ..............................Polyester

 

I

/0

 

(On/Off) switch................................Nylon 

 Casters....................................................Nylon

 

Oxygen product outlet ...................Aluminum

 Printed labels.............................Polycarbonate

 

Pipe/Tubing..........................Aluminium,PVC,           

                                    polyurethane or silicone

 

5.3. Operating principle

The  compressor  sends  filtered  room  air  to  a    

solenoid  valve, which allows compressed air to 

pass to the column in production. The columns 

contain a molecular sieve, whose function is to 

adsorb the nitrogen and thus allow oxygen to pass. 

The oxygen enriched product is then directed 

through a pressure reducing valve continuing 

to the oxygen product outlet fitting.    

During  this  time,  the  column  which  is  being 

"regenerated" is connected to the ambient air 

and flow of oxygen enriched product is passed 

through it (from the column "in production").  In 

this way, when one column is in production, the 

other is in a nitrogen desorption or "regenera-

tion" phase. The oxygen enriched product finally 

passes through a final product filter located prior 

to the oxygen outlet fitting.

5.4. Alarms - Safety devices - Indications
5.4.1. Alarms

• 

No voltage detection

In the event of a loss of mains power, an inter

-

mittent audible alarm is activated and the green 

light turns off.  Test alarm by actuating the 

I

/

(ON/OFF) switch when the power cord is not 

plugged into the wall outlet.

Summary of Contents for Pureline OC4000

Page 1: ...OC6000 Operators Manual Supera LLC Copyright 2019 OXYGEN CONCENTRATORS For Veterinary Use Only...

Page 2: ......

Page 3: ...away for help Our goal is to make your new machine as easy to use and care for as possible This device is meant to be operated under the normal surveillance and control of a veterinarian trained in it...

Page 4: ......

Page 5: ...th the 3 16 allen wrench provided VERY tightly 1 Carefully unpack the top assembly and frame from the box 2 Align the top to the frame as shown NOTE The frame base has two cross bars with holes in the...

Page 6: ...1 Remove the oxygen concentrator from the box and guide the 4 threaded post into the frame 2 Install and tighten the nuts DO NOT OVER TIGHTEN THE NUTS SNUG FIT IS ALL THAT IS NEEDED...

Page 7: ...Attach the green hose from the OC6000 top to the threaded fitting DO NOT OVER TIGHTEN Oxygen Setup Attach the green hose from your anesthesia machine to the DISS fitting...

Page 8: ...ch in the AUX position the supply of oxygen to the anesthesia machine comes from E tank on the back of the machine or another source using the E tank adapter p n OC6050 To use the E tank as a souce fo...

Page 9: ...F power switched off Class II protection Do not expose to open flames Do not use oil or grease Technical information Consult the accompanying documents Keep in the vertical position Fragile handle wit...

Page 10: ...manual should be allowed to operate the O2 concentrator TheCAUTIONSbelowindicateapotentially hazardous situation If conditions are not avoided a situation could occur that results in property damage o...

Page 11: ...Concentrator is packaged to protect the device from damage while being transported and stored Check for damage to the packaging After device is removed from the package inspect for damage If damage i...

Page 12: ...2 1 Front panel Fig 2 1 1 I O ON OFF switch 2 Indicator lights 3 Oxygen product outlet 4 Circuit breaker 5 Pre set flow meter non adjustable...

Page 13: ...s for ap proximatelyoneminuteafterthedeviceisstopped 1 Filter Silencer 2 Cabinet filter 3 Ventilation grill Note Shown with grate removed Fig 4 1 4 CLEANING MAINTENANCE Only the outside of the concent...

Page 14: ...he column in production The columns contain a molecular sieve whose function is to adsorbthenitrogenandthusallowoxygentopass The oxygen enriched product is then directed through a pressure reducing va...

Page 15: ...is fitted on the compressor outlet and is calibrated to 2 7 bar 40 psig 5 4 3 Indicators The green indicator light Fig 5 1 indicates that power is applied to the device When first turned on the indica...

Page 16: ...he maximum flow does not exceed 10 of the indicated value when a back pressure of 7 kPa 1 psig is applied to the output of the device The maximum outlet pressure is 50 kPa 7 psig 5 5 4 Maintenance of...

Page 17: ...ubeaxial fan cools the compressor compart ment Environmental limit conditions The performances of the device especially the oxygen concentration are quoted at 21o C 70o F and one atmosphere They may c...

Page 18: ...Pneumatic connection broken or other pressure problem Internal electrical fault Pneumatic circuit fault Dirty Filters blockage Fan is not working Observations The I O ON OFF button is in the I ON pos...

Page 19: ......

Page 20: ......

Page 21: ...machine This can be washed with mild soap and wa ter DO NOT INSTALL UNTIL 100 DRY P N 8400 1180 Fine inlet filter square black plastic filter List Price 14 95 The fine particle filter goes under the...

Page 22: ......

Page 23: ...al applicable for the product 3 products considered to be of a consumable nature such as rubber or plastic goods 4 accessories or parts not manufactured by Supera Anesthesia Innovations 5 specially ma...

Page 24: ...company s terminal where they are entirely responsible 5 Open and inspect your product as soon as possible DO NOT WAIT 6 If you find damage take as many photographs of everything as soon as you can a...

Page 25: ...DOCUMENTATION Date purchased Purchased from Machine serial number Machine service information Service Date Service information Service Date Service information Service Date Service information...

Page 26: ......

Page 27: ......

Page 28: ...OXYGEN CONCENTRATORS 503 723 5068 or 877 620 1500 toll free E Mail info superavet com 12330 S E Highway 212 Clackamas OR 97015 www SuperaVet com...

Reviews: