Summary of Contents for CLOUD 9 SMOKER

Page 1: ...CLOUD 9 SMOKER USER GUIDE 030402 THE VENTILATION SPECIALISTS...

Page 2: ...The CLOUD 9 SMOKER User Guide P N Rev 030402 Super Vacuum Manufacturing Co Inc P O Box 87 Loveland CO 80539 Phone 1 800 525 5224 Website www supervac com...

Page 3: ...moker Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 2 INTRODUCTION 3 3 BASIC DESCRIPTION 4 4 TECHNICAL SPECIFICATIONS 5 5 SETTING UP 6 6 GAS AND FLUID REQUIREMEN...

Page 4: ...e sent to your local freight agent for verification and investigation This time can be saved by your filling the claim directly Every consignee is on the ground floor and in contact with the local age...

Page 5: ...n of possible danger to the users if precautions are not observed As is customary in military and some commercial manuals the precautions will always precede the steps to which it refers so that the u...

Page 6: ...e integration of three electronic fail safe systems This design will protect against over and under heating conditions and component failures Also included is a pressure relief safety that will protec...

Page 7: ...Super Vac Oil based Smoker Fluid SVOSF Fluid tank capacity 0 66 US gal Gas consumption 2 13 lbs per hour at 40 psi ACC Auto Clean Cycle Particle size 1 micron Warm up time Maximum 10 minutes Operatin...

Page 8: ...and stored in an upright position on a stable and level surface Do not operate closer than six feet 6 ft from personnel The maximum operating pressure is 40 psi Use in a well ventilated area WARNING...

Page 9: ...egulator to a CO2 cylinder NOTE When operating the CLOUD 9 SMOKER using CO2 as a propellant the CO2 bottle must be in an upright position to prevent freezing of the regulator WARNING CO2 and N2 gases...

Page 10: ...ticles are mixed or added to the Super Vac fluid SVOSF CAUTION The Super Vac Oil based Cloud 9 Smoker Fluid produces a pure white non toxic smoke Use of this cloud 9 smoker with any other fluid will a...

Page 11: ...the fluid tank Now unscrew the red cap located on top of the unit and slowly pour the Super Vac Oil based Smoker Fluid SVOSF until it reaches the inside bottom of the opening Avoid overfilling screw b...

Page 12: ...ed will go off and the initial Auto Clean Cycle ACC will be automatically triggered After this initial cleaning cycle which will take approximately 30 seconds the unit will be ready to produce smoke T...

Page 13: ...rol is also adjusted at 12 o clock the production of smoke on will be for 5 min and smoke off 5 min The ready green led indicates that the CLOUD 9 SMOKER is ready to produce smoke The smoke on off swi...

Page 14: ...t the following sequence must be observed Turn off the smoke switch on the remote control timer Wait for the Auto Clean Cycle ACC to complete The recommended minimum ACC pressure is 10 psi Turn off th...

Page 15: ...installation overloading abuse or accident of any type or causes are not covered by this warranty All equipment manufactured by us is pre run and tested before leaving our plant and is shipped in good...

Page 16: ...14 11 CONTACT INFORMATION THE VENTILATION SPECIALISTS Fire End Croker Corp 7 Westchester Plaza Elmsford NY 10523 800 759 3473 Order on line at fire end com...