4-12
Publication: 0028607
SEWER CLEANING — TYPICAL SEQUENCE
4
10. OPTION: If your truck is equipped with the winter
recirculation option, connect the sewer hose to the
recirculation line (7) located on the front bumper.
Figure 4-27
11. Open the sewer hose valve and the drain valve (8)
behind the front bumper.
Figure 4-28
12. Open the air purge valve until you hear air enter the
water tanks. The winter recirculation line is now
clean. Close the air purge valve and the drain valve
behind the front bumper.
13. Unhook the sewer hose and dock the hose in the
travel fitting.
14. Close the sewer hose valve.
15. Open the drain under the front bumper to drain any
remaining water. Close the drain when finished.
16. Install the spray wand onto the front bumper
connection port (9) and squeeze the trigger until all of
the water is expelled.
Figure 4-29
17. OPTION: If the truck is equipped with a handgun
hose reel, connect the spray wand and open the
valve on the water pump. Squeeze the trigger until all
water is expelled. Remove the spray wand and close
the hand reel valve.
18. Open the heat exchanger drain valve (10). Close the
valve when all water has been expelled.
Figure 4-30
7
8
9
10
Summary of Contents for Camel 1200 (Dump Body)
Page 1: ......
Page 2: ......
Page 4: ......
Page 62: ...1 52 Publication 0028607 SAFETY 1...
Page 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...
Page 106: ...4 18 Publication 0028607 SEWER CLEANING TYPICAL SEQUENCE 4...
Page 118: ...5 12 Publication 0028607 WATER RECYCLING SYSTEM 5...
Page 132: ...6 14 Publication 0028607 LUBRICATION AND MAINTENANCE 6...
Page 156: ...i vi Publication 0028607 IX...
Page 157: ......