Absorption phase
In this phase the charge voltage must be maintained at UAbsorption to fully charge the
battery. If the charger currents drop below 5% (Imin) of the 1C current the absorption phase
can be maintained for t2 minutes, see Table 16.
Absorption Phase
Parameter
Typical
Min
Max
Remark
U
Absorption
14,6V DC
14,2V DC
14,8V DC
-
I
min
3% of 1C
-
5% of 1C
-
t
1
20 minutes
10 minutes
1 hour
-
t
2
10 minutes
5 minutes
30 minutes
-
Table 17. Absorption Phase
Float phase
In this phase the charge voltage is set to UFloat. If the battery voltage drops below UReturn
for longer than t4 seconds than the charging process has to be repeated.
Float Phase
Parameter
Typical
Min
Max
Remark
U
Float
13,5V DC
13,4V DC
13,6V DC
-
t
4
60 sec
5 sec
120 sec
-
Table 18. Float Phase
Optional maintenance phase
If supported by the charger, every t3 hours the charger can do a maintenance charge to
make sure that the batteries are kept fully charged.
Maintenance Phase
Parameter
Typical
Min
Max
Remark
t
3
720 hours
168 hours
4320 hours
-
Table 19. Maintenance phase