background image

7

Direct code table (D-Code)

The key lock function enables input operation control that prevents 
mistaken changes in the sensor settings. Also possible are minute 
settings such as ‘RUN adjust’, allowing threshold value adjustment 
only, and ‘RUN teaching’, allowing teaching operation only. 
If setting the sensor to ‘RUN adjust’ or ‘RUN teaching’, adjustments 
and teaching is possible with the sensor left in RUN mode.

Key lock function

Timer function

The built-in timer function cancels signals not needed for mark 
sensing and lengthens the width of signals to control devices.

m

The key lock function is enabled by pressing the MODE key and OFF key 
simultaneously for at least 2 sec. after having effectuated settings. Press the 
MODE and OFF keys again simultaneously for at least 2 sec. to release.

• 

ON-delay and OFF-delay timers built-in

• 

9 timer levels available: 1 ms / 2 ms / 5 ms / 10 ms / 20 ms / 50 ms / 100 ms / 

200 ms / 500 ms

High precision sensing and multiple functions provided all in a 
compact W57

D24

H38 mm 

W2.244

D0.945

H1.496 in

 

body. Cable and plug-in connector types are available depending on 
the equipment used. These sensors can be easily introduced to 
already existing facilities.

Compact design for significant space savings

• 

Built-in output 1 (OUT) and output 2 (OUT)

• 

Built-in teaching input

• 

NPN and PNP output types available

• 

With 5-core cable

• 

Built-in teaching input

• 

NPN and PNP output types available

• 

Straight and elbow type M12 plug-in 
connector cables available (optional)

Plug-in connector type

Cable type

M12 plug-in connector cable

Other features and handy functions

Timer period

Timer mode

Turn mode (Note 5)

ECO mode (Note 4)

Key lock

Display mode

2nd digit

3rd digit

4th digit

1st digit

Display

1 ms
2 ms
5 ms

10 ms
20 ms
50 ms

100 ms
200 ms
500 ms

non

OFF-delay

ON-delay

non

OFF-delay

ON-delay

non

OFF-delay

ON-delay

OFF

ON

OFF

ON

OFF

ON

OFF

ON

FINE

COARSE

FINE

COARSE

FINE

COARSE

FINE

COARSE

FINE

COARSE

FINE

COARSE

FINE

COARSE

FINE

COARSE

L-ON

D-ON

L-ON

D-ON

L-ON

D-ON

Consistent-ON

Inconsistent-ON

OFF

ON

OFF

ON

Mark mode (green)

Mark mode (blue)

Mark mode (red)

Color mode

Standard

Full lock

(All operations disabled)

RUN teaching

(Teaching only enabled)

Threshold value 
adjustment only enabled

RUN adjust

Display

Display

Display

Sensing mode (light source color) Operation mode (Note 1) Sensing (Note 2)

38 mm

1.496 in

24 mm

0.945 in

57 mm

2.244 in

Press at least 2 sec.

The sensor setting modes can be verified by a 4-digit code            
(D-Code). The table below shows a list of all available codes.

Percent display

(Note 3)

(                                   )

Notes: 1)

2)
3)
4)

5)

m

Default setting: D-code ‘        ’.

In Mark mode, L-ON / D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and press the 
OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON / D-ON.
Sensing accuracy can be set to either FINE (standard) or COARSE.
The percent display is only enabled in mark mode.
ECO mode is a function that reduces power consumption by turning off the digital display in the event no button operations are made for a 
predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again.
The turn mode is a function that reverses the digital display making it easily viewed in the event the sensor installation renders the display up-side-down.

● 

When in RUN mode, press the MODE 
key for at least 2 sec. to display the 
direct code. (Remove your finger from 
the MODE key and the direct code will 
disappear.)

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for LP-101-P-Z

Page 1: ...PHOTOELECTRIC SENSOR DIGITAL MARK SENSOR LX 100SERIES Introducing the ultimate mark sensor High resolution A D converter Automatic optimal LED selection function Conforming to EMC Directive Downloade...

Page 2: ...t emitting elements all in one The sensor s basic operations are represented by 6 indicator lamps MODE NAVI The user can check what mode the sensor is presently in with a quick glance rendering operat...

Page 3: ...ates ultra quick mark detection with a 45 s response time Color mode Mark mode A resolution of 1 4000 is realized to enable high precision mark sensing 3 large buttons that click into position making...

Page 4: ...ates this mark sensing The LX 100 series sensors automatically selects the optimal LED that will ensure the most stable sensing results Mark Light amount ratio Base 6 8 Mark Light amount ratio Base 8...

Page 5: ...o of the mark color The built in 12 bit A D converter enables high precision 1 4000 resolution judgments The figure below is a graphic description of this process 6 10 15 5 10 15 5 10 13 a Inconsisten...

Page 6: ...tor lamps MODE NAVI The user can check what mode the sensor is presently in with a quick glance rendering operation simple Sensing status digitally controllable The sensing status displayed numericall...

Page 7: ...ight up in order and each LED s reflected light is checked instantaneously The LEDs light up in order and each LED s reflected light is checked instantaneously Mode selection Press MODE key and select...

Page 8: ...200 ms 500 ms non OFF delay ON delay non OFF delay ON delay non OFF delay ON delay OFF ON OFF ON OFF ON OFF ON FINE COARSE FINE COARSE FINE COARSE FINE COARSE FINE COARSE FINE COARSE FINE COARSE FINE...

Page 9: ...ckets MS LX 1 Mating cables for plug in connector type sensor Two M4 length 28 mm 1 102 in screws with washers are attached MS LX 2 Two M4 length 30 mm 1 181 in screws with washers are attached 14 mm...

Page 10: ...porated Inverted operation of the output 1 Note Mating cable is not supplied with the plug in connector type Please order it separately Environmental resistance NPN output type NPN open collector tran...

Page 11: ...V DC 10 4 1 Load Load Terminal No of plug in connector type m1 Non voltage contact or PNP transistor or High 4 V to V sink current 3 mA or less Low 0 V to 0 6 V or open I O circuit diagrams 3 Layout...

Page 12: ...lash to indicate successful confirmation of settings To cancel settings press the MODE key ADJ Sensing level Standard Sensing level Coarse 50 ms 500 ms 100 ms 200 ms 20 ms 2 ms 1 ms 5 ms 10 ms Full lo...

Page 13: ...C 40 M 20 C 20 M 10 C 100 C 80 C 60 C 40 C 20 C 20 Y 10 C 100 Y 100 C 80 Y 80 C 60 Y 60 C 40 Y 40 C 20 Y 20 C 50 Y 100 C 40 Y 80 C 30 Y 60 C 20 Y 40 C 10 Y 20 Y 20 M 10 Y 20 BL 20 5 0 197 5 0 197 25...

Page 14: ...w spaces Detects meandering sheets using wide beam fiber The fiber amplifier is a 2 output type that can detect meandering in both the left and right directions Various mark sensing applications and s...

Page 15: ...deal for sensing objects moving on a conveyor belt High precision red laser sensor Its minute spot can effectively detect the presence of narrow cut tape Detects printed marks to align tubes Can be us...

Page 16: ...rared LED amplifiers available Various fibers available for any application Bright easy to view dual color digital display DP4 Improved functions and wide variations DP2 3 types of laser sensor heads...

Reviews: