7 Display and messages
38
Operation guide
· Press the
- or
-key to scroll screen and select
your submenu.
· Press
OK
-key to enter the setting mode which you
selected.
· Press the
-key to scroll numbers backwards
(from 9 to 0).
· Press the
-key to scroll numbers from 0 to 9.
· Press the
OK
-key to move from one digit to the
next (from left to right).
· Press the
OK
-key to confirm your input. (When it
is the last one). If your selection becomes opera-
tive, the LCD will give the message:
Setting OK !
Or else, the LCD will give the message, and your
selection will retain the previous setting.
Setting Lose!
Please check it!
Press the
ESC
-key to quit and go back to the previ-
ous menus.
5
The NTX inverter provided a RTC for recording
some data or events. Such as statistic and error
log, so the RTC’s accuracy is the internally logged
data. The time can be shown at default menu
and settings menu. When you find the data and
time is incorrect, you should enter settings menu
and correct it.
Date: 31-12-2000
Time: 00:00:00
Operation guide
· Press the
- or
-key to scroll screen and select
your submenu.
· Press the
OK
-key to enter the setting mode which
you selected.
· Press the
-key to scroll numbers backwards
(from 9 to 0).
· Press the
-key to scroll numbers from 0 to 9.
· Press the
OK
-key to move from one digit to the
next (from left to right).
· Press the
OK
-key to confirm your input. (When it
is the last one).
· Press the
ESC
-key to quit and go back to the
previous menus. You should ensure legitimacy of
time.
6
Tfl:100.00s
Fl:059.0Hz
Tfl: low frequency protect time.
Fl: low frequency.
Range:
300s≥Tfl≥0.16s
59.8Hz≥Fl≥57.0Hz
7
The NTX inverter provides “Ethernet monitor”
function. The factory defaults:
IP 192.168.1.2
Gateway 192.168.1.1
SubnetMask 255.255.255.0
User can modify or look at them through the
local LCD.
192.168.001.002
192.168.001.001
The first line is IP address and the second
line is Gateway. The SubnetMask is fixed at
255.255.255.0.
User can enter setting mode in this interface,
the setting method is analogous to time setting.
Prompt “setting OK” and “Restart Power Please
!” after setting.