![Sunways NT 2600 User Manual Download Page 74](http://html1.mh-extra.com/html/sunways/nt-2600/nt-2600_user-manual_1401174074.webp)
Technical data
Solar Inverter NT 2600
Recommended solar generator power
Rated input power
Stand-by consumption
Night-time consumption
AC energy generated from
Nominal voltage
U
MPP
voltage range
Open-circuit voltage
Switch-on voltage
Switch-off voltage
Maximum current
Nominal current
Number of inputs
Maximum efficiency
European efficiency (weighted)
HERIC
®
topology
Rated continuous output power Pn
Maximum power Pp
Nominal frequency
Grid voltage
Nominal current
Maximum current
Distortion factor at Pn
Reactive power factor (cos phi)
Output current
Model
1500 to 2750 W
2300 W
9 W
< 0,15 W
15 W
400 V
350
≤
U
MPP
≤
750 V
850 V
410 V
340 V
7 A
5,75 A
2 (with adapter: 4)
97 per cent
96,5 per cent
yes
2200 W
2200 W
50 Hz
230 V
9,6 A
9,6 A
< 3 per cent
~ 1
sinusoidal
DC
AC
160