Specification of excellent controller
Page - 8 -
4.
Confirm the connections are correct.
If wiring the load connection to a load distribution panel, each load circuit
should be fused separately. The total load draw current should not exceed
the 10A load rating.
Step 3
: Solar Module Wiring
WARNING
Risk of electric shock! Exercise caution when handling solar wiring. The solar
module(s) high voltage output can cause severe shock or injury. Cover the
solar module(s) from the sun before installing solar wiring.
CAUTION:
1. If you can not confirm the scientific and rational PV module connection by
series or parallel way, please contact the manufacturer of controller.
2. The controller can be applied to the single crystal silicon, polycrystalline
silicon, thin-film photo voltaic group
3. PV groups open circuit voltage (
Voc
) do not higher than rated battery bank
voltage 2.0times.
4. PV groups operation voltage (
Vmp
) do not lower than rated battery bank
voltage 1.2times.
Step 4
: Wind-turbine (PMG) Wiring
Figure 8 - 4
Figure 8 - 5