11.5

   

Press ―ENTER‖ key to next page: 

 

 

 

Press 

(+)  key  or 

(-)  key  to  adjust  the  number,  each  press  means 

increase or reduce 1 hour. Press ‗ENTER‘ to choose. 

 

11.6

   

Press ‗ENTER‘ key to next page:

 

 

 

 

 

Press 

(+)  key  or 

(-)  key  to  adjust  the  number,  each  press  means 

increase or reduce 1 hour. If set voltage, each press means increase or reduce 
1V . Press ‗ENTER‘ to choose. 

 
11.7

   

Press ‗ENTER‘ key to next page:

 

 

 

 

11.7.1

 

  ―VwTH‖ this value is mean controller would rise voltage of wind 

turbine  to  charge  battery.    Please  be  mind  if  your  system  are  24V,  will 
showing  is  12v,  it  was  rectified  value,  wind-turbine  output  approximate 
10vac.  12v  system,  will  showing6.0v.  wind-turbine  output  approximate 
6vac.   
 
Press 

(+)  key  or 

(-)  key  to  adjust  the  number,  each  press  means 

increase or reduce 1.0V.   

CAUTION: 
This  parameter  must  be  modify  by  professional  technician,  general 

user re-setting is prohibited! 
 

11.7.2

   

Mode parameter is meaning different system

   

Press 

(+) key or 

(-) key to choose mode type according to actual your 

system correctly !

 

T2-1:    Line2 whole power output time 

T2-2:    Line2 half power output time 

T2-1 :    xxh 
T2-2 :    xxh 

T2-3:    Line2 Turn-off output time 
VsTH

DC power output turn-on while 

voltage  of  solar  panel  lower  than  this 
value,  and  turn-off  while  solar  panel 
voltage higher than it 

T2-3 :    xxh 
VsTH :    xxV 

VwCH :    xxV 
MODE :    X 

Summary of Contents for SSWC-06-1224-TA

Page 1: ...el No SSWC 06 1224 TA Version 5 0 Thank you very much for selecting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please...

Page 2: ...ller 5 Step 1 Battery Wiring 5 Step 2 Loading Wiring 6 Step 3 Solar Module Wiring 7 Step 4 Wind turbine PMG Wiring 7 Step 5 Switch power wiring 8 Step 6 Accessories Option 8 Step 7 Confirmation for Wi...

Page 3: ...er than controller rating accordingly 2 General Safety Information Please don t use low quality battery to avoid leakage rust or burn Please don t use thin or low quality cable to avoid leakage or fir...

Page 4: ...light sensor voltage timer and so on 5 Protection Functions Solar cells reverse charging solar cells anti reverse connection Battery over charging over discharge battery anti reverse connection Over...

Page 5: ...er the controller Loose power connections and or corroded wires may result in resistive connections that melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and...

Page 6: ...h the drilled holes in step 4 Secure the controller in place using the mounting screws 8 3 System connection with controller NOTE A recommended connection sequence has been provided for maximum safety...

Page 7: ...ce will provide battery voltage to the loads DC loading could be LED lamp or monitor devices etc 1 Connect load1 positive and negative to the controller related terminals and connect load2 positive an...

Page 8: ...ause severe shock or injury Cover the solar module s from the sun before installing solar wiring CAUTION 1 If you can not confirm the scientific and rational PV module connection by series or parallel...

Page 9: ...e 2 wires from controller need connect to switch power Red wire is positive Black wire is negative polarity 2 Please make sure connection are correct with switch power related terminals 3 Switch power...

Page 10: ...power terminals are tightened Step 8 Power up sequence after confirmation of connection 1 Turn on battery firstly 2 Turn on solar panel 3 Turn on wind turbine 4 Turn on DC loading 5 Turn on switch po...

Page 11: ...ne 1 minute delay 4 If battery voltage lower than over discharge point no DC power output 5 As street lighting system while solar panel voltage higher than threshold voltage controller no DC power out...

Page 12: ...batteries Eb mean power volume of battery with percent format Uw meaning voltage of wind turbine but this value is DC voltage which be rectified voltage from wind turbine output Iw charging current f...

Page 13: ...d abnormal is troubleshooting the screen will automatically back to first browsing page content If the wind turbines in the brake protection status the screen display Tip Once the wind turbine brake a...

Page 14: ...the value each press means increase or reduce 0 1V Press ENTER to choose 11 3 Press ENTER key to next page Press key or key to adjust the number each press means increase or reduce 0 1V If set time ea...

Page 15: ...ill showing is 12v it was rectified value wind turbine output approximate 10vac 12v system will showing6 0v wind turbine output approximate 6vac Press key or key to adjust the number each press means...

Page 16: ...battery to power up controller This is intent to make sure the program running in you done modified setting condition PLEASE MAKE SURE NO CONNECTIION WITH WIND TURBINE AND SOLAR PANEL BEFORE SETTING...

Page 17: ...toT1 4 step T1 4 this process is balance of whole night time And turn off lamp while dawn This value would not show on LCD so this value is not adjustable Of course you could to cover this process by...

Page 18: ...ischarge Recovery Voltage 12V 24V 12 0V 24 0V adjustable Over charge Voltage 12V 24V 15 0V 30 0V adjustable Over charge Recovery Voltage 12V 24V 13 5V 27 0V adjustable 14 4 Output Set up function Each...

Page 19: ...rminals Inspect for loose broken or burnt wire connections Check and confirm that LCD is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective act...

Page 20: ...battery 2 Connected to the battery the controller does not output The battery voltage is below the release point Normal wait for the system to charge to the recovery point Access photovoltaic panels s...

Page 21: ...1 Damage by accident negligence abuse or improper use 2 PV or load current exceeding the rating of product 3 Unauthorized product modification attempted repair 4 Damage occurring during shipment 5 Dam...

Reviews: