OPERATION for electronic type 

 
Control panel

 

         

   

FIG.12 

 

1.  ON/OFF (power) button 
2.  Sign for dehumidification/water full 
3.  Sign for fan (ventilation) 
4.  Mode button  
5.  Sign for heat function 
6.  Sign for Centigrade or Fahrenheit 

(please refer to the real unit you 
purchased) 

7.  Swing button 
8.  Sign for sleep function 
9.  Sleep function button 
10.  “Temperature down”button 
11.  Room temperature display 

12.  Receiver for remote control 
13.  Timer display 
14.  “Temperature up”button 
15.  Timer 
16.  Sign for TiO2/ionizer (only for the unit with 

TiO2/ionizer) 

17.  TiO2/ionizer button (only for the unit with 

TiO2/ionizer function) 

18.  Fan speed display 
19.  Sign for automatic function 
20.  Fan speed button  
21.  Sign for cooling function 

 

Turning ON/OFF 
1. 

Press ON/OFF button, the unit will start automatically. If the ambient temperature is  

  higher than 23

o

C, the unit will work in cooling model. 

  higher than 20

o

C but below or equal to  23

o

C, the unit will work in ventilation 

model. 

  below 20

o

C, the unit will work in heating function (This is for cooling & heating 

models only.),  

Summary of Contents for Klimatronic Advance 2.9 MM plus

Page 1: ...Advance MM Advance 2 9 MM plus Advance 3 5 MM plus Read and retain these instructions for future reference...

Page 2: ...A Refrigerant load 525g 530g Fan speed 3 Timer electronic switch 1 24 hours Working temperature 18 32o C Exhaust pipe 142X1500mm Net Weight 31 kgs 32 kgs Dimension 450X365X825 mm WxDxH This appliance...

Page 3: ...NPLUG WHEN NOT IN USE DO NOT USE IN HUMID OR WET ENVIRONMENTS FIG 3 DO NOT PULL THE UNIT ALONG BY THE CORD IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PE...

Page 4: ...11 Inward adaptor piece 1 for connection with piece 2 and into back of the air conditioner 12 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 13 Round cap...

Page 5: ...rip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the...

Page 6: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length...

Page 7: ...t 2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the...

Page 8: ...Timer display 14 Temperature up button 15 Timer 16 Sign for TiO2 ionizer only for the unit with TiO2 ionizer 17 TiO2 ionizer button only for the unit with TiO2 ionizer function 18 Fan speed display 19...

Page 9: ...ow The sign of high low or medium ventilation will light on at the same time 2 If the unit is in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature Setti...

Page 10: ...first too Dehumidification function In dehumidification mode the temperature cannot be adjusted the ventilation will fix at low speed Heating function There are 2 different Heating characteristics dev...

Page 11: ...ises above the selected level the cooling will return to work 3 On the contrary the heating will switch off if the ambient temperature is higher than the set one still the ventilation keeps working on...

Page 12: ...rain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tra...

Page 13: ...it with another tube OD 18mm FIG 17 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Pleas...

Page 14: ...abinet Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thorough...

Page 15: ...ure Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible the overheat protection of the com...