background image

3. 

In sleep mode, the ventilation will keep at low speed. Re-press the SLEEP button, 
the setting temperature and ventilation speed will return to the pre-selected one. 

4. 

The unit will shut down automatically after the SLEEP function running for 12 hours. 

5. 

Please note, the sleep function is not available while the machine is working 
in ventilation, dehumidification or auto mode.  Only available in Cooling or 
Heating mode. 

6. 

When the machine is in Sleeping function, the Fan Speed would turn to be 
LOW speed. 

 
Swing function 
By pressing SWING button, the air vent will rise in 3 different angles: 60º

68º

75º 

Every time when you turn on the machine, the air vent will rise to position 75º first, then 
return to the pre-set position automatically.  If you reset the SWING button, the air vent 
will rise to position 75º first, too.    

 

Dehumidification function 

In dehumidification mode, the temperature cannot be adjusted, the ventilation will fix at 
low speed. 
 
Heating function 

There are 2 different Heating characteristics developed – Heat Pump (reverse type)  and 
PTC heater.   Only one function can be carried out in a machine. 

 

-  When using Heat Pump,  the ambient warm air  (usually spelled during the 
summer season) is recycled and use to heat the area where it is required.  The 
Exhaust Pipe must be still fitted to allow the cold air to be removed in this 
mode & used in the usual way
.    Under this system, the machine can run at 
HIGH/MED./LOW speed. 

 
-  When using PTC heater function, the machine can only run at MED. Speed.  

                                                             

TiO2 / Ionizer function 

1. 

This is only for the model with TiO2 or Ionizer function, i.e. model no.  with T or I.  T 
stands for TiO2, I stands for Ionizer.  * TiO2 is a kind of photochemical catalysis. 

2. 

To start the TiO2 or Ionizer button, please press TiO2/Ionizer button. These 2 
functions can clean the air, improve the air quality.  

 

 

 

 

 

 

 

10

 

 

 

Summary of Contents for Klimatronic Advance 2.9 MM plus

Page 1: ...Advance MM Advance 2 9 MM plus Advance 3 5 MM plus Read and retain these instructions for future reference...

Page 2: ...A Refrigerant load 525g 530g Fan speed 3 Timer electronic switch 1 24 hours Working temperature 18 32o C Exhaust pipe 142X1500mm Net Weight 31 kgs 32 kgs Dimension 450X365X825 mm WxDxH This appliance...

Page 3: ...NPLUG WHEN NOT IN USE DO NOT USE IN HUMID OR WET ENVIRONMENTS FIG 3 DO NOT PULL THE UNIT ALONG BY THE CORD IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PE...

Page 4: ...11 Inward adaptor piece 1 for connection with piece 2 and into back of the air conditioner 12 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 13 Round cap...

Page 5: ...rip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the...

Page 6: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length...

Page 7: ...t 2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the...

Page 8: ...Timer display 14 Temperature up button 15 Timer 16 Sign for TiO2 ionizer only for the unit with TiO2 ionizer 17 TiO2 ionizer button only for the unit with TiO2 ionizer function 18 Fan speed display 19...

Page 9: ...ow The sign of high low or medium ventilation will light on at the same time 2 If the unit is in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature Setti...

Page 10: ...first too Dehumidification function In dehumidification mode the temperature cannot be adjusted the ventilation will fix at low speed Heating function There are 2 different Heating characteristics dev...

Page 11: ...ises above the selected level the cooling will return to work 3 On the contrary the heating will switch off if the ambient temperature is higher than the set one still the ventilation keeps working on...

Page 12: ...rain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tra...

Page 13: ...it with another tube OD 18mm FIG 17 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Pleas...

Page 14: ...abinet Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thorough...

Page 15: ...ure Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible the overheat protection of the com...

Reviews: