background image

2. 

Indicators of the functions in progress come on at the same time. *NOTE! The 
display window shows the ambient room temperature from 0

o

C to 50

o

3. 

To turn the unit off, press ON/OFF button again. 

 

Setting mode/function 

Press MODE button to select required working mode: automatic, cooling, fan, 
dehumidification or heating, (Heating is only available for heating & cooling models.)  
Sign of your selected mode comes on. 
 
Setting temperature 

1. 

Press 'Temperature up' or 'Temperature down' button to regulate the temperature 
you desired. 

2. 

The display window will show the temperature you set as you press 'Temperature 
up' or 'Temperature down' button.  Otherwise, it will always show the ambient 
temperature. 

3. 

The pre-setting temperature of this machine is:  24

o

C for cooling, 20

o

C for heating.

 

 
 

Setting ventilation speed 

1. 

Press SPEED button to choose the ventilation speed you need, high, medium or 
low. The sign of high, low  or medium ventilation will light on at the same time. 

2. 

If the unit is in AUTO mode, it will choose the ventilation speed automatically 
according to the ambient temperature. 

 
Setting timer 

1. 

Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign 
of timer will light on). When the set time has been reached, the machine will turn off 
automatically. The LCD will show the hour(s) you set as you press TIMER button. If 
the timer button is not pressed, the unit will work continuously. 

2. 

By pressing the timer but without turning on the other functions, you can PRE-SET 
the time for the machine to work.  For example, if you press the timer to '2', the unit 
will work automatically after 2 hours. 

 
Sleep function 

1. 

In cooling mode, by pressing the SLEEP button, the set temperature will increase 
1

o

C at the 1st hour, another 1

 o

C at the second hour, then keeps at that 

temperature.  

2. 

In heat mode, by pressing the SLEEP button, the set temperature will descend 1

o

at the 1st hour, another 1

 o

C at the second hour, then keeps at that temperature.  

 
 
 

9

Summary of Contents for Klimatronic Advance 2.9 MM plus

Page 1: ...Advance MM Advance 2 9 MM plus Advance 3 5 MM plus Read and retain these instructions for future reference...

Page 2: ...A Refrigerant load 525g 530g Fan speed 3 Timer electronic switch 1 24 hours Working temperature 18 32o C Exhaust pipe 142X1500mm Net Weight 31 kgs 32 kgs Dimension 450X365X825 mm WxDxH This appliance...

Page 3: ...NPLUG WHEN NOT IN USE DO NOT USE IN HUMID OR WET ENVIRONMENTS FIG 3 DO NOT PULL THE UNIT ALONG BY THE CORD IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PE...

Page 4: ...11 Inward adaptor piece 1 for connection with piece 2 and into back of the air conditioner 12 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 13 Round cap...

Page 5: ...rip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the...

Page 6: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length...

Page 7: ...t 2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the...

Page 8: ...Timer display 14 Temperature up button 15 Timer 16 Sign for TiO2 ionizer only for the unit with TiO2 ionizer 17 TiO2 ionizer button only for the unit with TiO2 ionizer function 18 Fan speed display 19...

Page 9: ...ow The sign of high low or medium ventilation will light on at the same time 2 If the unit is in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature Setti...

Page 10: ...first too Dehumidification function In dehumidification mode the temperature cannot be adjusted the ventilation will fix at low speed Heating function There are 2 different Heating characteristics dev...

Page 11: ...ises above the selected level the cooling will return to work 3 On the contrary the heating will switch off if the ambient temperature is higher than the set one still the ventilation keeps working on...

Page 12: ...rain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tra...

Page 13: ...it with another tube OD 18mm FIG 17 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Pleas...

Page 14: ...abinet Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thorough...

Page 15: ...ure Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible the overheat protection of the com...

Reviews: