SunSun SuperEco JTP Series Operation Manual Download Page 5

Technical data 

Model

Item no.

Voltage

Power

 (W)

Max. head 

(m)

Output

 (

h

)

JTP-1800

51634

230 V/50 Hz

11

2,2

1800

JTP-2800

51635

18

3,0

2800

JTP-3800

51636

25

3,8

3800

JTP-4800

51637

32

4,5

4800

JTP-4000R

51638

25

3,2

4000

JTP-5000R

51639

30

3,6

5000

JTP-6000R

51640

40

4,0

6000

JTP-7000R

51641

50

4,4

7000

JTP-8000R

51642

60

4,8

8000

JTP-10000R

51643

80

6,0

10000

JTP-12000R

51644

100

6,5

12000

JTP-14000R

51645

120

7,0

14000

Notice!

There are 2 types for connection to inlet and outlet:

Type 1:

1. Loosen the screw nut clockwise. 
2. Connect the hose. 3.
3. Tighten the screw nut anticlockwise.

Type 2 (multi-stage connections):

1. Select the right size for the connection and cut off the smaller connections.
2. Connect the hose.

© by WilTec Wildanger Technik GmbH 

Item 51634-51645

Page 5 

http://www.WilTec.de

http://www.aoyue.eu

05 2021

-1

http://www.teichtip.de

Summary of Contents for SuperEco JTP Series

Page 1: ...ow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can diffe...

Page 2: ...ous languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods u...

Page 3: ...es are damaged or worn Never override safety devices Only use the appliance in accordance with the intended use specified in these instructions for use You are responsible for safety in the work area...

Page 4: ...e pond pump you have purchased is already equipped with a protective contact plug The pump is intended for connection to a 230 V 50 Hz earthed socket Make sure that the socket is sufficiently fused mi...

Page 5: ...4 8 8000 JTP 10000R 51643 80 6 0 10000 JTP 12000R 51644 100 6 5 12000 JTP 14000R 51645 120 7 0 14000 Notice There are 2 types for connection to inlet and outlet Type 1 1 Loosen the screw nut clockwis...

Page 6: ...the direction of the arrow and then pulling it off Fig 3 Move the snap lock on the base plate in the direction of the arrow Fig 4 Remove the base plate Fig 5 Turn the motor housing in the direction o...

Page 7: ...ing it off Fig 3 Remove the control valve in the direction of the arrow Fig 4 Move the snap lock on the base plate in the direction of the arrow Fig 5 Loosen the base plate Fig 6 Turn the motor housin...

Page 8: ...s out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the corre...