1.
Key functions:
MODE/FEED:
With a simple push you get to the selection menu; hold this button down for a
longer time to enter feeding mode.
NIGHT/LOCK:
With a simple push you get into night mode; long press this button to enter lock
mode.
The wave cycle and the type of wave can be set using the “Time function key” in the left half of the
control panel. The function key for the flow in the right half of the control panel controls the capa -
city.
2.
Mode functions:
Wave mode (A):
The "Time controller" function key and the "Flow controller" function key regulate
the flow and waveform. Turning the time control clockwise extends the wavelength. The flow regu-
lator can also affect the swing of the wave. By turning the “time regulator” counter-clockwise, the
wavelength becomes shorter.
Note:
It is advisable to fine-tune the “time controller” after the flow controller has been set to max -
imum. The device should be observed for at least 10 seconds after each fine-adjustment.
Random mode (B):
Hereby the power of the wave is changed at random. The flow and waveform
are also randomly influenced.
Constant flow mode (C):
Hereby the malfunction pump ensures a constant flow. The continuous
flow is set via the flow regulator.
Feeding mode:
Press the
“MODE/FEED”
button longer, the display now shows “10 Min.”, which
means that the flow pump is paused for 10 minutes; now you can feed the fish. After 10 minutes,
the flow pump automatically returns to the mode last set. To reset the flow pump to operation, hold
down
“MODE/FEED”
until the display goes out.
3.
Night/Lock functions:
Night mode:
A simple push of the button
“NIGHT/LOCK”
causes the night light to light up; the
flow pump changes to night mode: While working according to the respective setting during the
day, it works with minimum power at night. To exit night mode, simply press the
“NIGHT/LOCK”
button. The night light switches off.
Lock mode:
Holding down the
“NIGHT/LOCK”
button causes the
“LOCK”
display to light up and
the wavemaker pump to save the waveform and flow settings. To set the waveform and current
again, press
“NIGHT/LOCK”
until the display disappears.
Maintenance
Regularly clean and maintain the pump and related parts to extend their life. To do this, proceed as
follows:
1.
Disconnect the pump from the power supply by carefully pulling the plug out of the socket.
2.
Take the pump out of the water. To do this, grab the pump unit in the water with one hand and
the magnet on the outer wall of the aquarium with the other. Carefully slide both magnets
away from each other.
3.
Carefully open the pump unit. The rotor cover can be removed by sliding the lock on the pump
body. Clean it with a soft cloth and rinse the pump housing well with water.
4.
Carefully clean the individual elements, do not use detergents or impregnating agents!
5.
After cleaning, the pump must be reassembled in reverse order. Make sure that the two
grooves fit together and that the shaft sits correctly.
© by WilTec Wildanger Technik GmbH
Artikel 51656–51659
Seite 7
http://www.WilTec.de
http://www.aoyue.eu
11 2020
-1