34
⑺
Needle and needle guard(front)
When the end point of the looper comes to the center of
the left needle, adjust the end point of the looper to rise
1.5~2 mm higher than the needle. At this point, set the
clearance between the needle and the needle guard (F) at
0~0.3 mm.
[ Figure 59 ]
①
①
And, when the end point of the looper returns to the right needle, set the clearance with the needle guard (F) at 0~0.3 mm.
Adjustments can be done by untightening th screws (
②
,
③
).
※
Front/rear position of needle guard(R)
When the end tip of the looper comes to the center of the right needle, press the needle guard (R) to adjust the clearance
between the needle and the looper at 0~0.05 mm. At this point, be sure to set the distance between the left needle and the
needle guard (R) at 0~0.05 mm. Adjustments can be done by loosening the screws (
②
,
③
).
1.5~2.0mm
0~0.3mm
0~0.05mm
[ Figure 58 ]
[ Figure 57 ]
②
③
[ Figure 61 ]
[ Figure 60 ]
0~0.3mm
①
③
②