49
A. Loosen the screw
⑩
.
B. Adjust so that the side of the clamp spring
⑪
and the
side
⑫
of the moving blade
①
are aligned with each
other.
C. Tighten the screw
⑩
.
D. Loosen the screw
⑭
.
E. Adjust so that the side of the clamp spring pressure
⑬
is parallel to the side of the clamp spring
⑪
and the
moving blade
①
.
F. Set a clearance of 2.0mm between the end tip of the
clamp spring pressure
⑬
and the end tip of the fixed
blade.
G. Fix the screw
⑭
tightly.
(4) Position of clamp spring and clamp spring pressure
[ Figure 86 ]
①
⑪
⑪
⑬
⑬
⑮
⑪
⑩
⑭
⑫
2mm
2mm
[ Figure 87 ]
A. The looper thread is caught by the clamp spring after
trimming
B. To increase pressure, turn the screw
⑮
clockwise and
to decrease pressure, turn it counter-clockwise.
(5) Pressure adjustment of clamp spring
Before adjustments, always turn off the motor switch and check to make sure that the motor is in stop
mode.
Warning
If the looper thread is caught
securely after trimming, keep the
pressure to the minimum.
Caution