![SunStar SC9200 Series User Manual Download Page 36](http://html.mh-extra.com/html/sunstar/sc9200-series/sc9200-series_user-manual_1400328036.webp)
36
35) Adjusting of the lifting quantity between the
pressure foot and the upper feed dog
SCT9300 Series
1) Turn the pulley until the bottom of the feed dog is below the
upper side of needle plate.
2) Confirm that the bottom side of the small pressure foot is
close to the upper side of needle plate. If not, follow the next
steps.
3) Loosen the nut
②
.
4) Pull down the pressure foot lifting lever
③
until it is close to
the screw
①
.
To make the bottom side of the small pressure foot contact the
upper side of needle plate, adjust the height of the small
pressure foot by turning the screw
①
as required.
5) Return the pressure foot lifting lever
③
and tighten the nut
②
to fix the screw
①
safely.
6) Lift the pressure foot. Loosen the screw
④
.
7) Adjust the pressure foot lifting range(a) by the stopper
⑤
.
(Table 11)
8) Tighten the screw
④
.
SCT9200 Series
1) Turn the pulley until the bottom of the feed dog is below the
upper side of needle plate.
2) Loosen the nut
②
.
3) Pull down the pressure foot lifting lever
③
until it is close to
the screw
①
.
Adjust the pressure foot lifting range(a) by turning the screw
①
as required. (Table 11)
4) Return the pressure foot lifting lever
③
and tighten the nut
②
.
5) Lift the pressure foot. Loosen the screw
④
.
Adjust the stopper
⑤
to make it contact the pressure foot arm
⑥
. Tighten the screw
④
.
Table 11) Lifting quantity between the pressure foot
and the upper feed dog
Model
Height of the upper feed dog
SC(T)9214-03/333
5.5
SC(T)9316-03/233
5
SC(T)9316-A04/435K
7
[Figure 75]
[Figure 76]
⑥
④
⑤
③
①
②