85
13.10) NEEDLE BAR ADJUSTMENT
1) Adjusting the Lower Dead Stop of the Needle
Lower dead stop of the needle refers to the
lowest point of the needle movement. It is
important for timing of the needle and the
rotary hook and must be adjusted precisely.
Usually you don
’
t have to adjust it, but if the
lower dead stop is not correct, follow the
procedures below.
①
Turn the hand lever and set the angle of the
upper shaft signal board at 178
°
.
②
Install the lower dead stop gauge (included
in the SWF accessory kit).
③
Unscrew the needle bar holder and move
the needle bar up and down. Fix the holder
so that the needle bar softly touches the
upper part of the gauge.
Lower dead stop
gauge
Screw
Needle bar holder
Presser foot holder
Highest point stopper
Needle bar rubber cushion
L-wrench
Needle bar holder
2) Adjusting the Highest Point of the Needle
You have to adjust the highest point of the
needle if you adjusted the lower dead stop.
Unfasten the screw on the highest point
stopper and set the upper shaft angle at 0
°
.
Attach the rubber cushion and the highest
point stopper to the head frame. Tighten
the screw.
Use ONLY DB
×
×
K5 #11 needle for the lower dead stop gauge.
CAUTION
You should be able to see half or the entire needle hole from the gauge in the bobbin case
when the needle is at the lower dead stop.
CAUTION