11-12
2) Adjusting Y scope limit
①
Manually move the frame so the frame location pointer is at the frame origin indicated on the table (see
[Fig.11-22]). Distance between the first needle of the head #1 and the rear end clip of the frame (Y-axis)
should be around 16.5mm.
②
Adjust the origin detecting sensor at the front of the Y-axis cam roller guide as shown in [Fig.11-25] and
fasten the sensor base.
③
After adjusting the Y origin, turn on the main switch and press the Y frame movement key on the operation
box. When the frame reaches the limit of the Y scope, fix the position of the limit sensor on the back of the Y-
axis cam roller guide as shown in [Fig.11-26].
3) After adjustment, turn on the power and select MACHINE MAINTENANCE in the main function menu and
FRAME ORG in the sub menu to check if the X, Y scopes were correctly adjusted.
[Fig.11-25]
[Fig.11-26]
Y-axis sensor plate
Origin detecting sensor
Origin detecting sensor base screw
Sensor board
Limit sensor
Y frame
movement
key
FRAME Y