11-11
11-10) ADJUSTING X, Y SCOPE LIMITS
1) Adjusting X scope limit
①
Manually move the frame to a point, where the
right end of the frame clip is 45.5mm from the
center of the needle hole on the #1 bed (see
[Fig.11-22])
②
Adjust the origin detecting sensor on the left of the X-axis cam roller guide as shown in [Fig.11-23] and fasten
the sensor base.
③
After adjusting the X origin, turn on the main switch and press the X frame movement key on the operation
box. When the frame reaches the limit of the X scope (interval between heads- ex. 330.300.275.240mm, see
FRAME-X on the screen), turn off the machine. Fix the position of the limit sensor on the right of the cam
roller guide as shown in [Fig.11-24].
[Fig.11-23]
[Fig.11-24]
Origin detecting sensor
1mm
X-axis sensor plate
FRAME X
X frame
movement key
Limit sensor
base screw
Limit sensor
Sensor board
Center of the needle
hole on #1 bed
[Fig.11-22]