Floor Sensor (NTC 10K by default)
If external sensor is broken, the user can buy NTC sensor by themselves, the available sensor types are as
follows:
NTC 100K/25 (3m,NTC,R25=100KΩ±1%@25
℃
, B25/50=3950K±1%)
NTC 50K/25 (3m,NTC,R25=50KΩ±1%@25
℃
, B25/50=3950K±1%)
NTC 15K/25 (3m,NTC,R25=15KΩ±1%@25
℃
, B25/50=3950K±1%)
NTC 10K/25 (3m,NTC,R25=10KΩ±1%@25
℃,
B25/50=3950K±1%)
NTC 12K/25 (3m,NTC,R25=12KΩ±1%@25
℃,
B25/50=3950K±1%)
This sensor type can also be configured through the proprietary attribute FloorSensorType (0x1002) of
Thermostat Cluster (0x0201).
Key vibration level (OFF by default)
Set the level of vibration sensor under the buttons or buzzer level.
OFF: vibration or buzzer off
Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level
This level can also be configured through the proprietary attribute ButtonVibrationLevel (0x1001) of
Thermostat Cluster (0x0201).
Control type (Room sensor by default)
Control type means which temperature sensor the device refers to when it adjust temperature.
Room sensor:
adjust temperature refers to room temperature (factory default type), heating control depends
on the Hysteresis.
Floor sensor:
adjust temperature refers to floor temperature, heating control depends on the Hysteresis.
Room+Floor sensor:
adjust temperature refers to both room temperature and floor temperature. when either
the floor sensor temperature or room sensor temperature achieves the set temperature, the controller will stop
heating, otherwise when both floor sensor temperature and room sensor temperature < (the set temperature -
Hysteresis), the controller will heat.
This control type can also be configured through the proprietary attribute ControlType (0x1003) of Thermostat
Cluster (0x0201).
Temp compensation (0 by default)
The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do
temp compensation to room sensor and floor sensor.
Compensation range is -3 ~ +3
℃
. When set temperature using buttons: if the unit is degree Celsius, the step
value is 0.5
℃
, if the unit is degree Fahrenheit, the step value is 1
℉
(approximately equal to 0.5
6℃
).
This value can also be configured through the attribute LocalTemperatureCalibration (0x0010) of Thermostat
Cluster (0x0201), and through the proprietary attribute FloorSensorCalibration (0x1005) of Thermostat Cluster
(0x0201).
RePower status(last status by default)
Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure after power on again.
If set as “default”, device will go to default mode after power on again.
This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat
Cluster (0x0201).
Display Temp type (Home Temp by default)
This parameter defines which sensor temperature will be displayed on Home page.
Floor Temp: floor temperature (external sensor).
Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute TemperatureDisplay (0x1008) of
Thermostat Cluster (0x0201).
Operate Brightness (Mid Level by default)
The OLED display brightness when operate the device.
High Level, Mid Level, Low Level.
This brightness can also be configured through the proprietary attribute OperateDisplayLcdBrightness
(0x1000) of Thermostat Cluster (0x0201).
Display Temp Unit
The temperature unit of the displayed temperature of the device.
Available settings:
℃
,
℉
.
Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute TemperatureDisplayMode (0x0000) of
Thermostat User Interface Configuration (0x0204).
Display Auto Off
By factory setting, once the device goes to standby interface, if there is no operation within 30 seconds, the
display will go off automatically. If device operation mode is set to OFF Mode, and there is no operation within 2
minutes, the display will go off automatically.
Child Lock
On the Home Interface, press and hold both and buttons for over 10S, the Child Lock can be enabled
or disabled, when the Child Lock is enabled, the icon will appear at the upper right corner, otherwise the
icon will not appear.
This Child Lock can also be configured through the attribute KeypadLockout (0x0001) of Thermostat Cluster
(0x0201).
Short press button
to select the item would like to modify, then short
press move up and move down buttons
to modify value of selected
item, then short press button
to save and quit, short pressing button
only quits without saving.
F
4.9 OTHER SET
Select
OTHER SET on Home Interface to enter into OTHER SET interface as follow:
Internal
Over
Heat
Protection
To
ensure
the
safety
of
the
device
,
if
the
internal
temperature
of
the
device
(
not
displayed
on
the
interface
)
is
over
a
certain
value
during
heating
process
,
the
device
will
execute
a
short
temporary
action
to
turn
off
the
relay
,
and
the
icon
will
appear
on
the
interface
,
after
the
temperature
decreases
to
a
certain
value
,
the
device
will
recover
to
work.
Display Auto Off Function Activation
On the Home Interface, press and hold both and buttons for over 10S, during the process, the icon
will flash slowly, the Display Auto OFF function can be enabled or disabled, when the function is enabled, the
icon will be displayed, otherwise the icon will not be displayed.
This Display Auto Off can also be configured through the proprietary attribute 0x100B of Thermostat Cluster
(0x0201).
Select
Network Set on Home Interface to enter into Zigbee network management interface as follow:
4.10 Zigbee Configuration Introduction