background image

Floor Sensor (NTC 10K by default)

If external sensor is broken, the user can buy NTC sensor by themselves, the available sensor types are as 

follows:

NTC 100K/25 (3m,NTC,R25=100KΩ±1%@25

, B25/50=3950K±1%)

NTC 50K/25 (3m,NTC,R25=50KΩ±1%@25

, B25/50=3950K±1%)

NTC 15K/25 (3m,NTC,R25=15KΩ±1%@25

, B25/50=3950K±1%)

NTC 10K/25 (3m,NTC,R25=10KΩ±1%@25

℃, 

B25/50=3950K±1%)

NTC 12K/25 (3m,NTC,R25=12KΩ±1%@25

℃, 

B25/50=3950K±1%)

This sensor type can also be configured through the proprietary attribute FloorSensorType (0x1002) of 

Thermostat Cluster (0x0201).

Key vibration level (OFF by default)

Set the level of vibration sensor under the buttons or buzzer level.

OFF: vibration or buzzer off

Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level

This level can also be configured through the proprietary attribute ButtonVibrationLevel (0x1001) of 

Thermostat Cluster (0x0201).

Control type (Room sensor by default)

Control type means which temperature sensor the device refers to when it adjust temperature.

Room sensor:

 adjust temperature refers to room temperature (factory default type), heating control depends 

on the Hysteresis.

Floor sensor: 

adjust temperature refers to floor temperature, heating control depends on the Hysteresis.

Room+Floor sensor:

 adjust temperature refers to both room temperature and floor temperature. when either 

the floor sensor temperature or room sensor temperature achieves the set temperature, the controller will stop 

heating, otherwise when both floor sensor temperature and room sensor temperature < (the set temperature - 

Hysteresis), the controller will heat. 

This control type can also be configured through the proprietary attribute ControlType (0x1003) of Thermostat 

Cluster (0x0201).

Temp compensation (0 by default)

The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do 

temp compensation to room sensor and floor sensor.

Compensation range is -3 ~ +3

. When set temperature using buttons: if the unit is degree Celsius, the step 

value is 0.5

, if the unit is degree Fahrenheit, the step value is 1

 (approximately equal to 0.5

6℃

).

This value can also be configured through the attribute LocalTemperatureCalibration (0x0010) of Thermostat 

Cluster (0x0201), and through the proprietary attribute FloorSensorCalibration (0x1005) of Thermostat Cluster 

(0x0201).

RePower status(last status by default)

Device state after reset power of the device.

If set as “last status”, device will go to the status before power failure after power on again.

If set as “default”, device will go to default mode after power on again.

This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat 

Cluster (0x0201).

Display Temp type (Home Temp by default)

This parameter defines which sensor temperature will be displayed on Home page.

Floor Temp: floor temperature (external sensor).

Home Temp: indoor air temperature.

This status can also be configured through the proprietary attribute TemperatureDisplay (0x1008) of 

Thermostat Cluster (0x0201).

Operate Brightness (Mid Level by default)

The OLED display brightness when operate the device.

High Level, Mid Level, Low Level.

This brightness can also be configured through the proprietary attribute OperateDisplayLcdBrightness 

(0x1000) of Thermostat Cluster (0x0201).

Display Temp Unit

The temperature unit of the displayed temperature of the device.

Available settings: 

.

Home Temp: indoor air temperature.

This status can also be configured through the proprietary attribute TemperatureDisplayMode (0x0000) of 

Thermostat User Interface Configuration (0x0204).

Display Auto Off 

By factory setting, once the device goes to standby interface, if there is no operation within 30 seconds, the 

display will go off automatically. If device operation mode is set to OFF Mode, and there is no operation within 2 

minutes, the display will go off automatically.

Child Lock

On the Home Interface, press and hold both         and         buttons for over 10S, the Child Lock can be enabled 

or disabled, when the Child Lock is enabled, the icon        will appear at the upper right corner, otherwise the 

icon will not appear.

This Child Lock can also be configured through the attribute KeypadLockout (0x0001) of Thermostat Cluster 

(0x0201).

Short press button  

    

 to select the item would like to modify, then short 

press move up and move down buttons    

     

 to modify value of selected 

item, then short press button 

     

 to save and quit, short pressing button   

only quits without saving.

F

4.9 OTHER SET

Select  

     

OTHER SET on Home Interface to enter into OTHER SET interface as follow:

Internal

 

Over

 

Heat

 

Protection

To

 

ensure

 

the

 

safety

 

of

 

the

 

device

if

 

the

 

internal

 

temperature

 

of

 

the

 

device

 (

not

 

displayed

 

on

 

the

 

interface

)

 

is

 

over

 

a

 

certain

 

value

 

during

 

heating

 

process

the

 

device

 

will

 

execute

 

a

 

short

 

temporary

 

action

 

to

 

turn

 

off

 

the

 

relay

and

 

the

 

icon

      

will

 

appear

 

on

 

the

 

interface

 , 

after

 

the

 

temperature

 

decreases

 

to

 

a

 

certain

 

value

the

 

device

 

will

 

recover

 

to

 

work.

Display Auto Off Function Activation

On the Home Interface, press and hold both         and         buttons for over 10S, during the process, the icon        

will flash slowly, the Display Auto OFF function can be enabled or disabled, when the function is enabled, the 

icon        will be displayed, otherwise the icon will not be displayed.

This Display Auto Off can also be configured through the proprietary attribute 0x100B of Thermostat Cluster 

(0x0201).

Select   

    

Network Set on Home Interface to enter into Zigbee network management interface as follow:

4.10 Zigbee Configuration Introduction

Summary of Contents for SR-ZG9092A

Page 1: ...C RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETS...

Page 2: ...Warnings 4 Basic Function Introduction 4 1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes...

Page 3: ...lsius the step value is 1 if the unit is degree Fahrenheit the step value is 1 approximately equal to 2 7 30 24 12 00 20 18 00 16 22 30 18 Saturday Sunday 7 30 24 12 00 20 18 00 18 22 30 18 After the...

Page 4: ...tatus 0x1004 of Thermostat Cluster 0x0201 Display Temp type Home Temp by default This parameter defines which sensor temperature will be displayed on Home page Floor Temp floor temperature external se...

Page 5: ...x0002 of Thermostat 0x0201 is 1 3 The proprietary attribute 0x2002 Manufacturer Code 0x1224 of the cluster 0x0201 can be modified to configure whether it is away mode or at home Note Away Mode uses at...

Page 6: ...0 Heat State Proprietary Attributes Attribute Type Description Manufacturer code 0x0003 bool read only SceneValid If true the scene identified by CurrentGroup and CurrentScene is currently active i e...

Page 7: ...de after reset power of the device Value 0 default mode Value 1 last status before power off Default 0x1224 0x100B ENUM8 reportable DisplayAutoOffEnable 0 disable Display Auto Off function 1 enable Di...

Page 8: ...Mask of Electrical Measurement The Alarm Server cluster can generate the following commands 0x0802 int16S reportable read only ACCurrentOverload Alarms when the current is over a certain value 0 10 16...

Page 9: ...t temperature when energy save mode is selected The temperature schedule of auto mode energy save mode is not configured correctly 3 Current temperature is not executed when away mode is selected Chec...

Reviews: