background image

AWAY Mode:

 this mode means there is no person at home, to keep a certain indoor temperature, the user can 

set the deadline of away, it also can be considered as anti-freezing function, the recommended setting 

temperature is 4-10 degrees. The mode and temperature can be configured by Zigbee gateway.

DRYING Mode:

 The device will judge the set temperature for heating within a short period of time, or the mode 

and temperature can be configured by Zigbee gateway.

Under Home interface, meanwhile the device is at OFF mode 

   

 , press and hold move up and move down 

buttons 

     

at the same time for over 5 seconds to enter into System Setting Interface as follows:

4.2 System Setting Interface

Quit: on System Setting Interface short press button          to go back to Home 

interface.

Enter into set interface of each setting item: short press move up        or move 

down button        to select a setting item, then short press button        to enter 

into set interface of the selected item.  

F

4.3 Preview of Device Information

On System Setting Interface, user can enter into 

   

PREVIEW

 interface, the interface will display some 

basic configurations, energy consumption, date, floor temperature etc.

4.4 Auto Mode Schedule

When Auto Mode Schedule is valid, the device will control according to the set temperature of the schedule.

For instance, if user would like to keep room temperature at 18 degree Celsius during 18:00-23:00 on every 

Monday, and keep room temperature at 20 degree Celsius after 22:30 on every Monday, then user can set 

schedule by himself.

Schedule setting method 1:

 user can enters into   

   

schedule on System Setting Interface, the schedule 

interface is as follows:

Short press button             to select “Auto Schedule”, then short press button         to enter into Auto Mode 

Schedule weekly setting interface.

F

2.3 Standby Interface

If the device operation mode is set to any other mode except OFF Mode, and 
there is no operation within 2 minutes, the device will go to this standby 
interface.
Once the device goes to standby interface, if Display Auto Off function is 
enabled and there is no operation within 30 seconds, the display will go off 
automatically.
If the device operation mode is set to OFF Mode, and there is no operation 
within 2 minutes, the display will go off automatically.

• 

DO NOT install with power applied to device.

• DO NOT expose the device to moisture.

3.Safety & Warnings

4. Basic Function Introduction

4.1 Switch Operation modes

Short press         button on Home interface to switch operation modes: the icons of Away, Manual (Comfort), 

Automatic (Energy Save), Drying, OFF modes will be displayed alternatively for 3 seconds and last displayed 

mode will be selected, or just short press       button to select a desired mode when the modes’ icon displayed 

alternatively.Press and hold         button on Home interface for over 3 seconds to select Away mode directly, 

then press and hold        button for 3 seconds to quit Away mode. 

OFF Mode:

 this mode means that the device is under idle status. 

MANUAL Mode

: the device will control the heating system according to current set temperature. The 

temperature can be set by move up and move down button on the Home interface, or the mode and temperature 

can be configured by Zigbee gateway.

AUTO Mode:

 the device will control the heating system according to the configured time schedule,  or the mode 

can be configured by Zigbee gateway but the temperature can not be modified and sent by the gateway alone.

F

TIME/SHIFT button, to set time schedule of the device quickly and move down the cursor

: Function button, to confirm, save setting

: Mode button, to switch operation modes and quit

: Move up and move down buttons, 

when modify the set temperature under manual, drying, 

and away modes on Home interface, hold to increase or decrease temperature rapidly

2.Home Interface

Child

 

Lock enabled: 

Week display: MON, TUE, WED, THU, FRI, SAT, SUN

The set temperature: Set 28.5

Room temperature:           25.5℃

Floor temperature:

Operation modes:         ( AWAY),           (Automatic),    

       (Manual),           (Drying) ,           (OFF)

Heating status:          (Heating),          (Locked: heating 

forbidden),          

(Door is opened, heating forbidden)

Already added to a Zigbee network: 

2.2 Button Description

F

2.1 Home Interface

F

On Auto Day Schedule interface, short press button 

     

  to select the time or 

temperature that you would like to modify, then short press move up and move 

down buttons  

       

   to modify value, then short press button 

    

to save 

and quit, short pressing button  

    

 only quits without saving.

F

For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error 
remind “Time setting error!!!”. The default time schedules are as follows:
Monday ~ Friday

Schedule setting method 2: 

on System Setting Interface, meanwhile the device is under Auto Mode 

    

 

 

short press button 

     

  to enter into Auto Mode Schedule weekly setting interface quickly:

On Auto Mode Schedule weekly setting interface, use buttons   

    

and 

   

  to enter into schedule setting of a 

certain week as follows:

Summary of Contents for SR-ZG9092A

Page 1: ...C RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETS...

Page 2: ...Warnings 4 Basic Function Introduction 4 1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes...

Page 3: ...lsius the step value is 1 if the unit is degree Fahrenheit the step value is 1 approximately equal to 2 7 30 24 12 00 20 18 00 16 22 30 18 Saturday Sunday 7 30 24 12 00 20 18 00 18 22 30 18 After the...

Page 4: ...tatus 0x1004 of Thermostat Cluster 0x0201 Display Temp type Home Temp by default This parameter defines which sensor temperature will be displayed on Home page Floor Temp floor temperature external se...

Page 5: ...x0002 of Thermostat 0x0201 is 1 3 The proprietary attribute 0x2002 Manufacturer Code 0x1224 of the cluster 0x0201 can be modified to configure whether it is away mode or at home Note Away Mode uses at...

Page 6: ...0 Heat State Proprietary Attributes Attribute Type Description Manufacturer code 0x0003 bool read only SceneValid If true the scene identified by CurrentGroup and CurrentScene is currently active i e...

Page 7: ...de after reset power of the device Value 0 default mode Value 1 last status before power off Default 0x1224 0x100B ENUM8 reportable DisplayAutoOffEnable 0 disable Display Auto Off function 1 enable Di...

Page 8: ...Mask of Electrical Measurement The Alarm Server cluster can generate the following commands 0x0802 int16S reportable read only ACCurrentOverload Alarms when the current is over a certain value 0 10 16...

Page 9: ...t temperature when energy save mode is selected The temperature schedule of auto mode energy save mode is not configured correctly 3 Current temperature is not executed when away mode is selected Chec...

Reviews: