background image

Sunpak® Infrared Heaters 

14 

Trouble

 

Shooting

 

Remote

 

Controls

 

Error

 

Code:

 

Reason

 

Solution

 

Module

 

has

 

four

 

“beeps”

 

every

 

one

 

second

 

Warns

 

user

 

that

 

the

 

pilot

 

flame

 

sensor

 

detects

 

a

 

pilot

 

flame

 

already

 

present

 

when

 

ignition

 

sequence

 

is

 

initiated.

 

This

 

fault

 

will

 

also

 

occur

 

if

 

pilot

 

flame

 

sensor

 

on

 

main

 

control

 

module

 

is

 

shorted

 

to

 

ground

 

Adjust

 

the

 

sensor

 

electrode

 

to

 

3/16”

 

for

 

the

 

pilot

 

hood

 

and

 

3/8”

 

from

 

the

 

spark

 

electrode.

   

Make

 

sure

 

the

 

electrode

 

is

 

within

 

the

 

flame

 

zone.

 

Four

 

beeps

 

every

 

two

 

seconds

 

Warns

 

users

 

the

 

module’s

 

internal

  

temperature

 

has

 

exceeded

 

170

⁰  

F.

 

(77

)

 

Correct

 

Mounting

 

Angle

 

 

Page

 

4

 

Provide

 

Proper

 

Ventilation

 

 

Page

 

9

 

 

Allow

 

heater

 

to

 

cool

 

down

 

before

 

pressing

 

<Off>

 

then

 

<ON>

 

One

 

beep

 

every

 

four

 

seconds

 

Flame

 

Safety

 

Circuit

 

has

 

locked

 

out

 

Press

 

OFF

 

button

 

to

 

reset

 

then

 

ON

 

to

 

restart

 

heater

 

Each

 

Sunpak

 

TSR

 

comes

 

with

 

wireless

 

controls

 

pre

programmed

 

for

 

individual

 

heaters.

 

If

 

you

 

have

 

a

 

problem

 

with

 

the

 

remotes,

 

please

 

review

 

the

 

following:

 

1.

 

Make

 

sure

 

there

 

is

 

power

 

to

 

the

 

unit

 

through

 

the

 

7.5

 

VDC

 

plug

in

 

power

 

adapter.

 

2.

 

Make

 

sure

 

you

 

have

 

the

 

correct

 

control

 

for

 

the

 

heater.

  

Each

 

control

 

is

 

marked

 

with

 

a

 

number

 

corresponding

 

to

 

the

 

label

 

located

 

on

 

the

 

louver

 

end

 

of

 

the

 

heater.

 

3.

 

Make

 

sure

 

you

 

genially

 

press

 

the

 

<ON>

 

button

 

for

 

1

 

full

 

second

 

to

 

allow

 

the

 

control

 

to

 

respond.

  

4.

 

Make

 

sure

 

the

 

red

 

indicator

 

lights

 

up

 

while

 

pressing

 

the

 

<ON>

 

button.

 

Replace

 

batteries

 

if

 

necessary.

 

5.

 

Each

 

heater

 

comes

 

with

 

two

 

wireless

 

control

 

devices.

 

Try

 

the

 

other

 

control

 

device.

 

6.

 

Press

 

<OFF>

 

to

 

RESET

 

system

 

and

 

then

 

press

 

<ON>.

 

After

 

a

 

few

 

seconds

 

you

 

should

 

hear

 

an

 

audible

 

click

 

from

 

the

 

control

 

inside

 

the

 

heater

 

and

 

see

 

a

 

spark

 

at

 

the

 

pilot

 

behind

 

the

 

face

 

grille.

 

If

 

the

 

above

 

procedure

 

fails

 

to

 

get

 

results

 

it

 

may

 

be

 

necessary

 

to

 

re

program

 

the

 

heater

 

control.

 

The

 

diagram

 

on

 

page

 

3

 

of

 

these

 

instructions

 

shows

 

the

 

location

 

of

 

the

 

programming

 

button

 

inside

 

the

 

heater.

 

This

 

button

 

may

 

be

 

accessed

 

through

 

the

 

port

 

on

 

the

 

front

 

panel

 

of

 

the

 

heater.

 

A

 

small

 

rod

 

such

 

as

 

a

 

bent

 

heavy

 

duty

 

paper

 

clip

 

or

 

1/8

 

inch

 

pin

 

will

 

be

 

necessary

 

to

 

reach

 

the

 

button.

 

The

 

heater

 

control

 

communicates

 

using

 

a

 

series

 

of

 

beeps.

 

In

 

a

 

noisy

 

environment

 

these

 

beeps

 

may

 

be

 

hard

 

to

 

hear.

 

Though

 

these

 

beeps

 

are

 

helpful

 

they

 

are

 

not

 

necessary

 

for

 

programming

 

the

 

heater.

 

Programming

 

Remote

 

Control

 

Devices

 

1.

 

Select

 

the

 

wireless

 

device

 

you

 

want

 

the

 

use

 

with

 

the

 

heater.

 

2.

 

Locate

 

the

 

learn

 

button

 

of

 

the

 

heater

 

control

 

as

 

shown

 

in

 

the

 

diagram

 

on

 

page

 

3.

 

With

 

the

 

bent

  

paper

 

clip,

 

press

 

and

 

hold

 

the

 

learn

 

button

 

for

 

6

 

seconds

 

before

 

releasing.

 

Summary of Contents for S34?TSR

Page 1: ...ler must provide a copy of this manual to the owner Owner Keep this manual in a safe place in order to provide your service technician with the necessary information Warning These instructions are intended for qualified personnel specifically trained and experienced in the installation and repair of this type of equipment and related system components For Assistance Call Toll Free 888 317 5255 Inf...

Page 2: ...oughly before installing or servicing this equipment Storage of gasoline and other flammable vapors and liquids in the vicinity of this or any other appliance may result in fire or explosion DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Always maintain clearance to combustibles as specified WARNING Not for indoor residential use T...

Page 3: ...followed by the ON button and the HI button Always PRESS the button for at least 1 second to allow proper transmission of the remote signal Device Battery Wall Remote 2032 Button Type Handheld 21 23 12V Sunpak heaters have a spark ignition and electronic flame safety control The pilot is only ON while the heater is operating If the flame safety sensor fails to sense flame at the pilot the heaters ...

Page 4: ...heater may be mounted at up to a 30 degree angle or face down Note that the top clearances required from combustible material increases when heaters are at any angle The heater must always be horizontal to the floor Never mount the heater in the vertical position Breezy conditions must be considered when heating any patio Windbreaks can be extremely effective in increasing comfort and reducing hea...

Page 5: ...Sunpak Infrared Heaters 5 ...

Page 6: ...Sunpak Infrared Heaters 6 Warning Heater must be level in the lengthwise direction ...

Page 7: ...e C22 1 Part 1 applies Gas Supply The gas inlet supply pressure and manifold pressure required for each heater are listed below For gas supply line pressures in excess of psig consult with your gas service provider or the factory Gas Inlet Pressure Nat Gas Propane Maximum Pressure psig psig Minimum Pressure 6 W C 11 W C Manifold Pressure 5 W C 10 W C It is critical that the gas piping system be ad...

Page 8: ...l and state plumbing and heating codes regarding sizing of gas lines 3 All gas pipe connections to the heater s must be sealed with a gas pipe compound resistant to liquefied petroleum gases 4 Installation of a drip leg or sediment trap in the gas supply line going to each heater is required to minimize the possibility of any loose scale or dirt within the gas supply line from entering the heater ...

Page 9: ...l page 8 and Basic Wiring page 10 2 Start Heater a Turn ON manual gas valve b Genially press the ON button of the remote control for 1 second c Allow heater 5 minutes to full warm up in full daylight it may be difficult to see the flame d If heater locks out press the OFF Button to RESET Heater and repeat start up sequence e If the heater locks out several times there may still be air in the gas l...

Page 10: ...s not water proof and must be weather protected The extension wire can be run 50 feet with 18 GA and must have suitable outdoor insulation In order to add the extension wire you must 1 Remove the Face Trim 2 Disconnect the Power Adapter from the control module 3 Attach the slide connector to the extension wire 4 Connect one end of the extension wire cable to the module and the other end to the Pow...

Page 11: ...Sunpak Infrared Heaters 11 ...

Page 12: ...Sunpak Infrared Heaters 12 ...

Page 13: ...DC to heater Heater lights but turns off Loose or broken ground wire Secure ground wire to heater body Control System Page 11 Pilot Electrode Adjust pilot electrodes 3 16 from pilot hood and 3 8 apart Swap sensor and spark connections on module Replace TSR Control Module Replace Pilot Electrode Assembly Sunpak Pilot Page 15 Control Components Page 11 Not Enough Heat Low Gas Pressure Verify require...

Page 14: ...el located on the louver end of the heater 3 Make sure you genially press the ON button for 1 full second to allow the control to respond 4 Make sure the red indicator lights up while pressing the ON button Replace batteries if necessary 5 Each heater comes with two wireless control devices Try the other control device 6 Press OFF to RESET system and then press ON After a few seconds you should he...

Page 15: ...does not light repeat procedure 4 It is likely that there is still air in the gas line If the heater fails to light or fails to stay lit after several tries it may be necessary to purge the air from the gas line using safe practices Sunpak Pilot The two electrodes near the pilot provide for flame ignition and sensing It is important that these electrodes be position properly Electrodes should be l...

Page 16: ... charges for forwarding the new heater or replacement part from the nearest distributor and returning the claimed defective heater or part to such distributor c All cost necessary or incidental for handling and administrative charges and for any materials and or permits required for installation of the replacement heater or part LIMITATION ON IMPLIED WARRANTIES Implied warranties including any war...